Samsung RM255BASB, RM255BABB manual If Ice Cubed or/and Ice Crushed dont work normally

Page 70

DIAGNOSTIC

6-9) If Ice Cubed or/and Ice Crushed don't work normally

Start

It operates with the Freezer door closed.

Does ice come out when drawing ice?

NO

YES

Is there ice in the ice storage bin?

 

NO

 

 

 

 

 

 

Is the ice selection on panel

NO

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for ice off?

 

 

Check point of contact of ice drawing S/W

 

 

 

 

 

 

 

 

 

 

Check point of contact of door S/W.

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check point of contact of ice transfer motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Release the icing stop Select ice

 

 

Check point of contact for wiring of the ice transfer motor

 

 

 

 

 

 

 

 

 

ice cubed/crushed

 

 

crushed ice

 

 

 

 

 

 

 

 

 

What is the ice status on the panel Display?

 

 

 

 

 

 

 

1) Check water supply hose. - bent or turned off.

 

cubed ice

 

 

2) Check water supply parts for icing solenoid check

 

 

 

 

 

 

 

3) Check icemaker wire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do ice cubed come out when

YES

Does crushed ice come

 

YES

 

 

out when pulling ice out?

 

 

 

 

 

drawing ice?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

Normal working condition

 

 

 

 

Normal Working Condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does MAIN MICOM No. 14

 

NO

 

 

 

change to 0V when pressing ice s/w?

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check ice s/w has failure itself.

 

 

 

 

 

 

 

 

 

 

- Check connected.

 

 

 

 

 

- Main PCB failure: Replace it.

 

 

 

 

 

 

 

 

 

 

 

NO

Does MAIN MICOM No. 17 change to

0V when pressing and holding ice s/w?

 

 

 

 

 

 

 

 

 

Measure both terminals of RY7C

 

 

YES

 

 

 

 

contact point after disconnecting CN72

 

 

 

 

Main PCB failure: Replace it

and CN73 connectors.

 

 

 

 

(IC74 failure).

 

 

 

 

 

 

 

 

 

 

 

Is the contact terminal of RY7E

 

NO

 

 

 

relay 0 when pressing ice s/w?

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- RY7E relay failure

 

 

 

 

 

- Main PCB failure: Replace it.

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal Main PCB

- Need to check other sections.

Check the wire between AUGER MOTOR and MAIN PCB. Failure of CUBE MOTOR itself or connecting connector contact failure.

Does Main MICOM No. 14 change

No

 

to 0V when pressing ice s/w?

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main PCB failure: Replace it.

 

 

 

Did cube motor move to ice crushed

No

location? (Load MICOM No. 28 is 5V?)

 

 

 

 

 

 

 

 

 

- When LOAD MICOM No. 28 is 0V continuously,

 

YES

 

CUBE MOTOR and IC74 should be checked.

 

 

 

- Check CUBE MOTOR S/W.

 

 

 

 

 

- Check CN73,CN40 WIRE.

 

 

 

Does IC74 No. 17 change to 0V

No

when pressing and holding ice s/w?

 

 

 

 

 

 

 

 

 

Main PCB failure: Replace it (IC74 Failure).

 

YES

 

Measure the both terminals of RY7E contact point

 

 

 

 

 

 

 

 

after disconnecting CN72 and CN73 connectors.

 

 

 

Is RY7E RELAY contact terminal

No

0even when power off?

 

 

 

 

 

 

 

 

 

 

 

YES

 

Main PCB failure: Replace it.

 

 

(RY7E Relay contact terminal short failure)

 

 

 

 

 

Normal Main PCB

- Need to check the other sections.

Check the wire between AUGER MOTOR and MAIN PCB. Failure of CUBE MOTOR itself connector contact failure.

69

Image 70
Contents RM255BARB RM255BASB RM255BABB Authorized Training Center Campuses Important Safety Notice Contents Precautionssafety Warnings Symbols Forbidden Product Specifications This operation instruction covers various models ManualRM25 Model SpecificationAfter packing 386lbs Electric Parts Specification SensorItems Specifications Model Dispenser Home BarElectric Components RunningPhotograph Optional Material SpecificationsPart Code Operating Instructions & Installation Temperature Control Operation Digital PanelPower cool Operation Power Freeze and Power cool OperationPower Freeze Operation By in inside function irrespective of current settingAble to operate on front panel At Initial Power OnLock Function Cube / Crushed / ICE OFF Selection FunctionLight Operation Machine Room F-Fan Motor Delay FunctionWater Dispenser Function Load Operation ConditionHorizontal position Interval about 880ms Initial OperationReverse rotation CCW Forward rotation CW Ice extraction Maximum torsion pointIce Extraction Function Water Supply FunctionIce-Making Function Water Supply TimeBold numerals indicate relevant ice tray steps Horizontality operation Arctic Zone Defrosting FunctionDefrosting period is fixed to 8 hours 53.6 62.6Operation Arctic Select Zone FunctionFunction Fresh Select Zone FunctionTest KEY Function Operation SpecificationTemp .8 ~ 44.6 of the Fridge compartment Operation startForced Defrosting Function For the R compartmentWhen water supply is finished, in the ice maker test mode Alarm FunctionCommunication Error Display Function Display Function at PanelOperating Instructions & Installation Self-Diagnostics FunctionSelf-Diagnostics Checklist BAD Item Trouble StatusSensor of R ErrorDefrosting CR SensorOn Error CF-FAN ErrorCR-FAN Error TroubleLoad Condition Display Function Load Mode Checklist Load Item Load StatusRelevant displays about load status is as follows Changing to Optional Mode Option Setting FunctionKEY Function Value ItemTemperature Change Table for the Freezer Compartment Change for freezer compartmentTemperature Change Table for the Refrigerator Compartment KEYMaker For Ice Maker CR Room Temperature Shift FunctionCase of basic model, the following items cannot be set Flow sensorDisassembly and Reassembly Removing the Front Leg Cover Door AssyRemoving the Freezer Door Removing the Refrigerator Door Remove two screws holding it to Open the Fresh Select Zone DoorLiner on the right side of the rail To separate it Reattaching the Freezer Door Reattaching the Refrigerator Door Levelling Open the Arctic Select Zone Door ZoneWater line must be connected to drinkable water only Do not overtighten the compression Note nutClose the filter cartridge cover Door Handle Door Sub PartsControl Panel Door GasketTempered Glass Shelf Refrigerator Door Light SwitchRefrigerator Light Plastic Drawers in the RefrigeratorDoor Bin in Freezer Freezer Door Light SwitchFreezer Compartments Plastic Drawer in FreezerTighten the screws 2 of the ice maker support Ice Dispenser Ice MakerFreezer Light Auger Motor Case Upper DuctworkPartition in the Freezer Screws Pull the upper part of the evaporator cover slightlyEvaporator Fan Motor Evaporator in FreezerIce-Maker Thermistor Freezer ThermistorThermistor cover Screw Water TankEvaporator cover in the Refrigerator Evaporator Fan Motor in RefrigeratorDuctwork Thermistor Thermistor cover Evaporator in FridgeRefrigerator Thermistor Fresh /Arctic Select ZoneTM ThermistorUpper Ductwork Sub-condenser Machine Compartment Electric BoxPCB-MAIN Assy Water SolenoidsRemoving the Arctic Select Zone Accessories Normal If power is not onStart Check at the Smps PBA Check Main PCB connectionExchange and repair COMP. Assembly Check connector for Contact failureIf the compressor doesn’t work normally Reference Perform forced defrosting for F R room one at a timeIf there is a trouble with self-diagnosissensor failure If the ambient temperature sensor has troubleHow To Check Temperature Sensing in the manual Check the soldering on the main PCB for Shorts & breaksIf Beep sounds continuously Start Alarm Sounds continuouslyrelated to the buzzerIf Ding-Dong sounds continuously Start Gasket, food etcBuzzer is broken - replace it If the buzzer doesn’t soundMain PCB is normal, buzzer is Normal Replace buzzer or panel PCBIf the panel PCB is not working normally Where the Panel PCB key isn’t selectedIt is a care Door Open 0V DC If fan motor doesn’t working normalyDoor S/W ConditionThese signals will be inputted into Micom Door Open DCIf Ice Cubed or/and Ice Crushed dont work normally If Indoor Lamp of Freezer/Refrigerator doesn’t light Replace Inside lamp Replace or troubleshoot Door S/WIf Water Drawer doesnt work normally Preliminary Check If Dispenser LED Lamp doesnt light Replace connector Wire and switchReplace connector and wire Failure of panel PCB itselfWiring Diagram Connector Arrangement Main Board Circuitschematic Diagram Conn Ector Arrangement SMP S Board Power BUS A voltage proportional to68.2 98.993.7 40.0 88.9 38.2 84.2 36.4 79.8 34.6 75.7 32.8 71.8 64.7#18 GND0.8V IC75 Input IC75 Output FAN107 Comparison in HIGH/LOW Speed Motor Drive Circuit DescriptionsPrinciple of Operation RemarksXAA 13-2 Q & a Problem Possible Causes What To Do Reference InformationProblem Possible Causes What To Do Small or hollow cubesCompressor Sub-condenser Hot Pipe Dryer Step valve Additional InformationSuction Pipe Freezer Refrigerator