A. Input power freeze/regular condetion key. When power freeze startes, LED signal change at once. (Comp and
B. During quick freezing the refrigerator controlled by setted notch.
A. Judge the temp. of F/R room, F room is over comp on of“LOW”NOTCH or R room is over comp on of“LOW”NOTCH. If so regular condition function isn’t performed and LED is OFF below 0.5 seconds.
B. Input the function, judge temp. of F room or R room, F room is less than comp on of“LOW”NOTCH and R room is less than comp on of“LOW”NOTCH. If so regular condition function is operate and comp
C. When state the operation of regular condition, judge the temp. of F/R room, F room is over comp on of“LOW”NOTCH or R room is over comp on of“LOW”NOTCH. If son regular condition function is the end and it is returned before.
4)Power refrigerator/Power saving function
1)Select power refrigerator/power saving button
2)Press POWER/SAVING BUTTON at once. And it is selected“OFF”“Power refrigerator”“Saving operation”.
3)Initial power on isn’t signal.
CLASSIFICATION | INITIAL POWER ON | PRESS ONE | PRESS T ONE | NOTES |
|
|
|
|
|
CHANGE OF SIGNAL LAMP | OFF | POWER REFRIGERATOR | SAVING OPERATION NOTES |
|
|
|
|
|
|
A. Input power refrigerator/saving key. When power refrigerator started, LED signal change at once.
(Comp. and
A. Input saving operation button, F/R room temp. operate 0.8℃ rising. (When situation about NOTCH, rised 0.8℃)
B. When input power freezer or power refrigerator, saving function stop to the end of power function and saving operation is performed after the end of power function.
※When power freeze and refrigeration selected at the same time
-Each function applied at the same time Power freeze runs Comp. and
3.Alarming
1)Button