3.In case of FAN in the refrigerator doern’t run
REFRENCES
“Be sure to check cooling FAN under forced operation”
1.Freezer FAN, refrigerator FAN and COMP COOLING are off when COMP is off.
2.Though the COMP is on, the FAN is not always on because the FAN is off when the temperature was reached to the set point (Forced operation included)
3.There isn’t delaying time to run the fan after door open (COMP on state)
A. In case of
START
Select Forced operation
Forced operation
Does it run after the door S/W pressed?
Does the door S/W works nomally
Change Door S/W
In MAIN PCB connection O.K?
Output MICOM pin 19 sigral?
Change lead and MICOM change PCB
Is 5V the IC3(KA2657) #16 singval?
IC3(KA2657) Failure
Check ssr(SSR71), Change
MAIN PCB ASSY