Cleveland Range CSTK-610CA manual CSTK-1010CA

Page 2

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Gas Table Type Models

(OGB 6.10 on OGB 10.10 or OGS 6.10 on OGS 10.10)

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

 

Model #

Description

 

CSTK-1010

for mounting one 6.10 model on top of one 10.10 model

byCleveland

CSTK-1010CA

for mounting one 6.10 model on top of one 10.10 model (with casters)

LEFT SIDE VIEW

39.21"

UNIT A

G

D

W1 W2

RC

CS

 

 

UNIT B

 

 

48.54”

4.38"

 

 

 

 

 

 

REQUIREMENT)

 

78.41"

 

80.00”(MIN. HOOD

 

 

 

 

2.52"

28.43

5.00"

38.98"

6.00"

36.70"

 

1.58"

1.82"

 

UNIT A

 

UNIT B

G D W1 W2

RC CS

NOTE: Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

 

Electrical Requirements:

120 volt, 60 Hz, single phase, UNIT A - 11.7 amps

 

Do not connect to a G.F.I. outlet.

 

UNIT B - 11.7 amps

 

 

 

 

G

Gas Connection:

3/4" NPT

 

 

Gas Type:

Natural Gas (Propane optional)

 

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

 

 

Propane Gas - Min. 11" WC / Max. 14" WC

 

BOILER MODELS

UNIT A - OGB-6.10

UNIT B - OGB-10.10

 

Total Connected Load:

45.400 BTU

75,700 BTU

 

Steam Generator:

45.400 BTU

68,200 BTU

 

Hot Air:

45.400 BTU

75,700 BTU

 

 

 

 

 

BOILERLESS MODELS

UNIT A - OGS-6.10

UNIT B - OGS-10.10

 

Total Connected Load:

45.400 BTU

75,700 BTU

 

Hot Air:

45.400 BTU

75,700 BTU

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

D Drain Connection:

2" Tube

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

CS *Connection for Cleaning Solution

RC *Connection for Rinse Cycle

*Available as an option

Note: For additional connection details, see spec sheet for each individual combi model to be stacked.

SECT. IIB PAGE 5B 0707

1333 East 179 St.,

Tel: 1-216-481-4900

Web Site: www.ClevelandRange.com

Cleveland, Ohio, U.S.A. 44110

Fax: 1-216-481-3782

Email: Steam@ClevelandRange.com

Image 2
Contents Water Connections CSTK-610CAGas Connection Drain ConnectionCSTK-1010CA CSTK-620CA For mounting two 6.20 models with castersCSTK-1020CA Connection for Cleaning Solution ModelsUnit B OEB-10.10 Drain Connection Tube Venting Exhaust Hood required Available as an option See spec sheet for each individualUnit B OEB-10.20