Cleveland
COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 10.10 or OGS 6.10 on OGS 10.10)
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
| Model # | Description |
| for mounting one 6.10 model on top of one 10.10 model | |
byCleveland |
| for mounting one 6.10 model on top of one 10.10 model (with casters) |
LEFT SIDE VIEW
39.21"
UNIT A
G | D | W1 W2 | RC | CS |
|
| UNIT B |
|
|
48.54”
4.38"
|
|
|
|
|
|
REQUIREMENT) |
| |
78.41" | ||
| ||
80.00”(MIN. HOOD |
| |
|
|
|
2.52"
28.43
5.00"
38.98"
6.00"
36.70" |
|
1.58" | 1.82" |
| |
UNIT A |
|
UNIT B |
G D W1 W2 | RC CS |
NOTE: Overall height of unit does not change for units with casters.
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"
•Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
•Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
•Installation must comply with all local fire and health codes.
| Electrical Requirements: | 120 volt, 60 Hz, single phase, UNIT A - 11.7 amps | |
| Do not connect to a G.F.I. outlet. |
| UNIT B - 11.7 amps |
|
|
|
|
G | Gas Connection: | 3/4" NPT |
|
| Gas Type: | Natural Gas (Propane optional) | |
| Gas Flow Pressure: | Natural Gas - Min. 5.5" WC / Max. 14" WC | |
|
| Propane Gas - Min. 11" WC / Max. 14" WC | |
| BOILER MODELS | UNIT A - | UNIT B - |
| Total Connected Load: | 45.400 BTU | 75,700 BTU |
| Steam Generator: | 45.400 BTU | 68,200 BTU |
| Hot Air: | 45.400 BTU | 75,700 BTU |
|
|
|
|
| BOILERLESS MODELS | UNIT A - | UNIT B - |
| Total Connected Load: | 45.400 BTU | 75,700 BTU |
| Hot Air: | 45.400 BTU | 75,700 BTU |
|
|
|
|
| Water Connections: | Cold Water (drinking water quality) |
| Flow Pressure: | 30 - 60 PSI |
| Water Inlets: | 3/4" |
| W1 | Treated Water for Steam Generator |
| W2 | Untreated Water for Condenser |
|
|
|
D Drain Connection: | 2" Tube | |
|
|
|
| Venting: | Exhaust Hood required |
|
|
|
CS *Connection for Cleaning Solution
RC *Connection for Rinse Cycle
*Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5B 0707
1333 East 179 St., | Tel: | Web Site: www.ClevelandRange.com |
Cleveland, Ohio, U.S.A. 44110 | Fax: | Email: Steam@ClevelandRange.com |