Cleveland
COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.10 on OEB 6.10 or OES 6.10 on OES 6.10)
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
| Model # | Description |
| for mounting two 6.10 models | |
byCleveland |
| for mounting two 6.10 models (with casters) |
LEFT SIDE VIEW
37.83"
UNIT A
D | W1 W2 | RC | CS |
| UNIT B |
| 38.08" |
|
|
| |
|
|
| 4.38" |
|
|
|
|
|
|
|
|
HOOD REQUIREMENT) |
|
| |
67.85" | |||
78.00”(MIN. |
|
| |
|
| ||
|
|
|
|
2.52"
28.43
5.00"
28.43
6.00"
36.70" |
|
1.58" | 1.82" |
| |
UNIT A |
|
UNIT B |
D W1 W2 RC CS
NOTE: Overall height of unit does not change for units with casters.
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"
•Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
•Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
•Installation must comply with all local fire and health codes.
Electrical Requirements: | Do not connect to a G.F.I. outlet. |
|
|
| |||||
BOILER |
| UNIT A - |
|
| UNIT B - |
|
| ||
|
|
|
|
| |||||
MODELS |
| 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 |
|
| ||||||||
Total Connected Load: |
| 9.9 KW | 12.8 KW | 11 KW | 13.1 KW | 9.9 KW | 12.8 KW | 11 KW | 13.1 KW |
Hot Air: |
| 8.6 KW | 11.4 KW | 9.1 KW | 10.2 KW | 8.6 KW | 11.4 KW | 9.1 KW | 10.2 KW |
Steam Generator: |
| 7.7 KW | 10.2 KW | 8.6 KW | 10.2 KW | 7.7 KW | 10.2 KW | 8.6 KW | 10.2 KW |
Amps per Phase: |
| 27.3 | 30.8 | 15.2 | 16.3 | 27.3 | 30.8 | 15.2 | 16.3 |
|
|
|
|
|
|
|
| ||
BOILERLESS |
| UNIT A - |
|
| UNIT B - |
|
| ||
MODELS |
| 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 |
|
| ||||||||
Total Connected Load: |
| 9.9 KW | 12.8 KW | 11 KW | 13.1 KW | 9.9 KW | 12.8 KW | 11 KW | 13.1 KW |
Hot Air: |
| 8.6 KW | 11.4 KW | 9.1 KW | 10.2 KW | 8.6 KW | 11.4 KW | 9.1 KW | 10.2 KW |
Amps per Phase: |
| 27.3 | 30.8 | 15.2 | 16.3 | 27.3 | 30.8 | 15.2 | 16.3 |
|
|
|
|
|
|
|
|
|
|
| Water Connections: | Cold Water (drinking water quality) | |||
| Flow Pressure: | 30 - 60 PSI |
|
| |
| Water Inlets: | 3/4" | |||
|
| Connection) |
|
| |
| W1 | Treated Water for Steam Generator | |||
| W2 | Untreated Water for Condenser | |||
|
|
|
|
| |
D | Drain Connection: | 2" Tube |
|
| |
|
|
|
| ||
| Venting: | Exhaust Hood required | |||
|
|
|
| ||
CS | *Connection for Cleaning Solution |
|
| ||
|
|
|
|
|
|
RC | *Connection for Rinse Cycle |
|
|
|
|
|
|
|
|
|
|
| *Available as an option |
|
|
|
|
| Note: For additional connection details, |
|
|
| |
|
|
|
| ||
| see spec sheet for each individual |
| SECT. IIB PAGE 5E | ||
| combi model to be stacked. |
|
| 0707 |
1333 East 179 St., | Tel: | Web Site: www.ClevelandRange.com |
Cleveland, Ohio, U.S.A. 44110 | Fax: | Email: Steam@ClevelandRange.com |