Cleveland Range CSTK-610CA manual Drain Connection Tube Venting Exhaust Hood required

Page 7

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.20 on OEB 6.20 or OES 6.20 on OES 6.20)

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

byCleveland

Model #

Description

CSTK-620

for mounting two 6.20 models

CSTK-620CA

for mounting two 6.20 models (with casters)

LEFT SIDE VIEW

46.34"

UNIT A

D

W1 W2

RC

CS

 

UNIT B

 

 

 

 

 

39.50"

 

 

 

4.38"

 

 

 

 

 

 

REQUIREMENT)

 

71.20"

 

78.00”(MIN. HOOD

 

 

 

 

2.52"

30.12"

5.00" 30.12"

6.00"

FRONT VIEW

47.92"

 

1.58"

1.82"

 

 

UNIT A

UNIT B

D W1 W2 RC CS

NOTE: Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Water Connections:

Flow Pressure:

Water Inlets:

W1

W2

Cold Water (drinking water quality) 30 - 60 PSI

3/4" GHT-F (Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

Electrical Requirements:

Do not connect to a G.F.I. outlet.

 

 

 

BOILER

 

UNIT A - OEB-6.20

 

 

UNIT B - OEB-6.20

 

 

 

 

 

 

 

MODELS

 

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

Total Connected Load:

 

16.4 KW

21.6 KW

18.5 KW

22 KW

16.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

 

14.7 KW

19.6 KW

16.5 KW

19.6 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Steam Generator:

 

12.8 KW

17.1 KW

14.3 KW

17.1 KW

12.8 KW

17.1 KW

14.3 KW

17.1 KW

Amps per Phase:

 

45.5

51.8

24.2

26.4

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

BOILERLESS

 

UNIT A - OES-6.20

 

 

UNIT B - OES-6.20

 

 

MODELS

 

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

Total Connected Load:

 

16.4 KW

21.6 KW

18.5 KW

22 KW

16.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

 

14.7 KW

19.6 KW

16.5 KW

19.6 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Amps per Phase:

 

45.5

51.8

24.2

26.4

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

 

 

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

see spec sheet for each individual

SECT. IIB PAGE 5G

 

combi model to be stacked.

 

0707

1333 East 179 St.,

Tel: 1-216-481-4900

Web Site: www.ClevelandRange.com

Cleveland, Ohio, U.S.A. 44110

Fax: 1-216-481-3782

Email: Steam@ClevelandRange.com

Image 7
Contents Drain Connection CSTK-610CAGas Connection Water ConnectionsCSTK-1010CA For mounting two 6.20 models with casters CSTK-620CACSTK-1020CA Models Connection for Cleaning SolutionUnit B OEB-10.10 Available as an option See spec sheet for each individual Drain Connection Tube Venting Exhaust Hood requiredUnit B OEB-10.20