Cleveland
COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
byCleveland
Model # | Description |
for mounting one 6.20 model on top of one 10.20 model | |
| for mounting one 6.20 model on top of one 10.20 model (with casters) |
LEFT SIDE VIEW
46.34"
UNIT A
D | W1 W2 | RC | CS |
| UNIT B |
|
|
48.32"
4.38"
|
|
|
|
|
|
|
|
REQUIREMENT) |
|
| |
80.09" | |||
|
| ||
81.00” (MIN. HOOD |
|
| |
|
|
|
|
2.52"
30.12"
5.00"
38.98"
6.00"
FRONT VIEW
47.92" |
|
1.58" | 1.82" |
| |
| UNIT A |
UNIT B |
D W1 W2 | RC CS |
NOTE: Overall height of unit does not change for units with casters.
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"
•Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
•Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
•Installation must comply with all local fire and health codes.
Water Connections:
Flow Pressure:
Water Inlets:
W1
W2
Cold Water (drinking water quality) 30 - 60 PSI
3/4"
Treated Water for Steam Generator
Untreated Water for Condenser
Electrical Requirements: Do not connect to a G.F.I. outlet.
BOILER | UNIT A - |
|
| UNIT B - |
| |||
MODELS | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 |
| ||||||||
Total Connected Load: | 16.4 KW | 21.6 KW | 18.5 KW | 22 KW | 26.3 KW | 34.9 KW | 29.4 KW | 34.9 KW |
Hot Air: | 14.7 KW | 19.6 KW | 16.5 KW | 19.6 KW | 25.8 KW | 34.3 KW | 28.8 KW | 34.3 KW |
Steam Generator: | 12.8 KW | 17.1 KW | 14.3 KW | 17.1 KW | 20.5 KW | 27.3 KW | 22.9 KW | 27.3 KW |
Amps per Phase: | 45.5 | 51.8 | 24.2 | 26.4 | 77.8 | 88.8 | 41.4 | 44.9 |
|
|
|
|
|
| |||
BOILERLESS | UNIT A - |
|
| UNIT B - |
| |||
MODELS | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 |
| ||||||||
Total Connected Load: | 16.4 KW | 21.6 KW | 18.5 KW | 22 KW | 26.3 KW | 34.9 KW | 29.4 KW | 34.9 KW |
Hot Air: | 14.7 KW | 19.6 KW | 16.5 KW | 19.6 KW | 25.8 KW | 34.3 KW | 28.8 KW | 34.3 KW |
Amps per Phase: | 45.5 | 51.8 | 24.2 | 26.4 | 77.8 | 88.8 | 41.4 | 44.9 |
|
|
|
|
|
|
|
|
|
D | Drain Connection: | 2" Tube |
|
|
|
|
|
| |
| Venting: | Exhaust Hood required | ||
|
|
|
| |
CS | *Connection for Cleaning Solution |
|
| |
|
|
|
|
|
RC | *Connection for Rinse Cycle |
|
|
|
|
|
|
|
|
| *Available as an option |
|
|
|
| Note: For additional connection details, |
|
| |
|
|
| ||
| see spec sheet for each individual | SECT. IIB PAGE 5H | ||
| combi model to be stacked. |
| 0707 |
1333 East 179 St., | Tel: | Web Site: www.ClevelandRange.com |
Cleveland, Ohio, U.S.A. 44110 | Fax: | Email: Steam@ClevelandRange.com |