Cleveland Range CSTK-610CA manual Unit B OEB-10.20

Page 8

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

byCleveland

Model #

Description

CSTK-1020

for mounting one 6.20 model on top of one 10.20 model

CSTK-1020CA

for mounting one 6.20 model on top of one 10.20 model (with casters)

LEFT SIDE VIEW

46.34"

UNIT A

D

W1 W2

RC

CS

 

UNIT B

 

 

48.32"

4.38"

 

 

 

 

 

 

 

 

REQUIREMENT)

 

 

80.09"

 

 

81.00” (MIN. HOOD

 

 

 

 

 

 

2.52"

30.12"

5.00"

38.98"

6.00"

FRONT VIEW

47.92"

 

1.58"

1.82"

 

 

UNIT A

UNIT B

D W1 W2

RC CS

NOTE: Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Water Connections:

Flow Pressure:

Water Inlets:

W1

W2

Cold Water (drinking water quality) 30 - 60 PSI

3/4" GHT-F (Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

Electrical Requirements: Do not connect to a G.F.I. outlet.

BOILER

UNIT A - OEB-6.20

 

 

UNIT B - OEB-10.20

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

Total Connected Load:

16.4 KW

21.6 KW

18.5 KW

22 KW

26.3 KW

34.9 KW

29.4 KW

34.9 KW

Hot Air:

14.7 KW

19.6 KW

16.5 KW

19.6 KW

25.8 KW

34.3 KW

28.8 KW

34.3 KW

Steam Generator:

12.8 KW

17.1 KW

14.3 KW

17.1 KW

20.5 KW

27.3 KW

22.9 KW

27.3 KW

Amps per Phase:

45.5

51.8

24.2

26.4

77.8

88.8

41.4

44.9

 

 

 

 

 

 

BOILERLESS

UNIT A - OES-6.20

 

 

UNIT B - OES-10.20

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

Total Connected Load:

16.4 KW

21.6 KW

18.5 KW

22 KW

26.3 KW

34.9 KW

29.4 KW

34.9 KW

Hot Air:

14.7 KW

19.6 KW

16.5 KW

19.6 KW

25.8 KW

34.3 KW

28.8 KW

34.3 KW

Amps per Phase:

45.5

51.8

24.2

26.4

77.8

88.8

41.4

44.9

 

 

 

 

 

 

 

 

 

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

see spec sheet for each individual

SECT. IIB PAGE 5H

 

combi model to be stacked.

 

0707

1333 East 179 St.,

Tel: 1-216-481-4900

Web Site: www.ClevelandRange.com

Cleveland, Ohio, U.S.A. 44110

Fax: 1-216-481-3782

Email: Steam@ClevelandRange.com

Image 8
Contents CSTK-610CA Gas ConnectionWater Connections Drain ConnectionCSTK-1010CA CSTK-620CA For mounting two 6.20 models with castersCSTK-1020CA Connection for Cleaning Solution ModelsUnit B OEB-10.10 Drain Connection Tube Venting Exhaust Hood required Available as an option See spec sheet for each individualUnit B OEB-10.20