description

possible cause

 

 

 

 

 

 

E-10

cavity air sensor shorted

Cavity air sensor reading < 5°F. Verify sensor integrity.

 

 

 

See sensor test instructions below.

 

 

E-11

cavity air sensor open

Cavity air sensor reading > 517°F. Verify sensor integrity.

 

See sensor test instructions below.

 

 

 

 

 

E-20

product probe is shorted

Product probe reading < 5°F. Verify sensor integrity.

 

Oven will cook in time only

See sensor test instructions below.

 

 

 

 

E-21

product probe is open

Product Probe reading > 517°F. Verify sensor integrity.

 

Oven will cook in time only

See sensor test instructions below.

 

 

 

 

E-30

Under temperature

Unit has not reached (set-point - 25°F) for more than 90 minutes.

 

 

 

 

Unit has been higher than 25°F above the maximum cavity set-point for

 

E-31

Over temperature

more than 2 minutes. Note: Holding Cabinets with this error code are

 

 

 

more than 145°F higher than the maximum set-point.

 

 

E-50

Temp. measurement error

Contact factory.

 

 

E-51

Temp. measurement error

Contact factory.

 

 

E-60

Real time clock error

Data set to factory default. Ensure that date and time are correct if applicable.

 

 

E-61

Real time clock error

Contact factory.

 

 

E-64

clock is not oscillating

Contact factory.

 

 

 

configuration connector

Refer to wiring diagram for the particular model and ensure dip switches on

 

E-70

the control match the settings called out on the WD. If the dip switch settings

 

error (dIp switch)

 

 

are correct according to the print replace the control.

 

 

 

 

 

E-78

Voltage low

Voltage below 90 VAC on a 125 VAC unit, or below 190 VAC on a

 

 

 

208-240 VAC unit. Correct voltage.

 

 

E-79

Voltage high

Voltage over 135 VAC on a 125 VAC unit, or over 250 VAC on a

 

 

 

208-240 VAC unit. Correct voltage.

 

 

E-80

EEpROM Error

Ensure that all temperatures and times are properly set.

 

 

 

Contact factory if problem persists.

 

 

E-81

EEpROM Error

Contact factory.

 

 

E-82

EEpROM Error

Contact factory.

 

 

E-83

EEpROM Error

Contact factory.

 

 

E-85

EEpROM Error

All timers, if previously on, are now off. Possible bad EEPROM.

 

 

E-86

EEpROM Error

Stored HACCP memory corrupted. HACCP Address reset to 1. Possible bad

 

 

 

EEPROM. Contact factory if problem persists.

 

 

E-87

EEpROM Error

Stored offsets corrupted. Offsets reset to 0. Control may need a recalibration.

 

 

 

Possible bad EEPROM. Contact factory if problem persists.

 

 

E-88

EEpROM Error

All timer set-points are reset to 1 minute. Timers, if previously on, are now

 

 

 

off. Possible bad EEPROM.

 

 

E-90

Button stuck

A button has been held down for >60 seconds. Adjust control. Error will

 

 

 

reset when the problem has been resolved.

 

 

E-dS

datakey error

Datakey digital signature incompatible. Cycle power, and install compatible

 

 

 

Datakey if error persists.

 

 

E-dT

datakey error

Datakey incompatible with control. Install compatible Datakey.

 

 

E-dU

datakey unplugged

Install Datakey and cycle power to control to clear error.

 

 

dLto

datalogger has timed out

Cycle power. Contact factory if error persists.

 

 

dLSd

Micro Sd card not plugged in

Plug in SD card and cycle power. Contact factory if error persists.

 

Note: If in doubt, always cycle the power to the control and contact factory if the problem persists.

To test probe and air sensor:

Test probe and air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale. The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs to be replaced.

pg. 28

TH/III installation/operation/service manual

Image 30
Contents Installation Sanitation L I V E R y P a c K I N gSAFETy pROcEdURES PREcAUTIONS N g E RMetal Parts of THiS EQUiPMENT Become Extremely HOT WhenT e Installation 300-TH/III500-TH/III 750-TH/III 1000-TH/III 37 940mmWeight 1200-TH/IIIOptions and Accessories 300-TH/III 500-TH/III 750-TH/III 1000-TH/III 1200-TH/IIIStacking Configurations STAcKINg INSTRUcTIONSModel Can be stacked with Risk of ELEcTRIc ShOcK Appliance must be secured To building structureDrip tray installation instructions 500, 750, 1000 Hard wired models Regarding International Standard UnitsECT R Ical Warranty Becomes VOiD iF APPLiANCE iS Flooded Audible signalsTo Clean Severe dAMAgE or ELEcTRIcAL hAZARd COULd ResultIndicator gf h i j k b c d e Operating Features & Functions Probe Usage Probe CalibrationSous Vide Cooking To Cook/Hold using Preset Menu Keys Cook/Hold InstructionsProgramming a Preset Erasing a PresetFahrenheit or Celsius Selection Preset Keys Lock and UnlockBeeper Volume Selection Control Panel Lock and UnlockHaccp Documentation, Data Logger Optional To download the data collectedOPE R a T IoN CLEANERS, or Cleaners CLEANINg AgENTSCLEANINg Materials PROTEcTINg Stainless Steel SURFAcESClean Daily Equipment CareClean the Probes Daily Check the Cooling Fan in the Oven Control AreaSafefood Internal Food Product Temperatures N i t a t i o nTroubleshooting To test probe and air sensorCode Description Possible cause Display is lit but unit is not heating Trouble shooting Internal Electrical ComponentsNo power. Display will not light To test air sensorR V ICE Exterior service view 300-TH/III a Description QTYExterior service view 500, 750, 1000-TH/III B 500-TH/III ShownExterior service view single compartment B PLUG, DOME,.187 HoleExterior service view double compartment C Exterior service view 1200-TH/III C Gasket Adhesive 0.125 XElectronic Components 300-TH/III 230V ShownElectronic Components 500, 750, 1000, 1200-TH/III Haccp data logger op t io nCable Heating Kits Cable heating kit #4880 #4881Page Page Page Page Page Page Page Page TransPortatIon DaMaGe and claIMs
Related manuals
Manual 50 pages 13.82 Kb Manual 59 pages 13.69 Kb Manual 41 pages 10.02 Kb Manual 41 pages 16.79 Kb Manual 41 pages 29.61 Kb Manual 2 pages 10.41 Kb Manual 2 pages 60.86 Kb Manual 2 pages 508 b

300-TH/III, 1200-TH/III, 500-TH/III, 750-TH/III, 1000-TH/III specifications

The Alto-Shaam 1200-TH/III is a revolutionary piece of equipment designed to meet the demands of modern commercial kitchens, blending innovative technology with user-friendly features. Renowned for its versatile capabilities, this model stands out as a reliable solution for restaurants, deli operations, and other foodservice establishments seeking to enhance their cooking and holding processes.

At the heart of the Alto-Shaam 1200-TH/III is its advanced Halo Heat technology. This patented system provides uniform heat distribution while maintaining the perfect serving temperature for a variety of foods. Unlike traditional holding equipment that uses aggressive heat sources, the Halo Heat system gently surrounds food with radiant heat, ensuring it remains moist and flavorful without excessive cooking or drying out. This is particularly beneficial for items such as meats, poultry, and prepared side dishes.

The 1200-TH/III features a capacity that is ideal for high-volume operations, with ample space to hold multiple pans of different sizes. This flexible space allows operators to maximize efficiency during peak service times. The unit is designed to accommodate a variety of food presentation styles, making it suitable for buffet setups, catering, or quick-service environments.

Another commendable feature of the Alto-Shaam 1200-TH/III is its user-friendly digital control panel. The intuitive interface allows for precise temperature control and monitoring, enabling staff to maintain optimal food conditions with minimal training. With programmable settings, users can easily establish different temperature profiles for various food items, streamlining the management of food service operations.

The construction of the Alto-Shaam 1200-TH/III emphasizes durability and ease of maintenance. Built from high-quality stainless steel, it resists corrosion and wear from daily use. Additionally, its removable racks and smooth surfaces facilitate easy cleaning, ensuring compliance with health regulations and promoting a hygienic kitchen environment.

Energy efficiency is another highlight of the Alto-Shaam 1200-TH/III. The innovative design not only reduces energy consumption but also contributes to lower operational costs, making it an economically sound choice for foodservice businesses.

In summary, the Alto-Shaam 1200-TH/III combines advanced technology with practical features to provide a top-tier solution for food holding and serving. Its Halo Heat technology, ample capacity, user-friendly controls, durable construction, and energy-efficient operation make it an essential addition to any commercial kitchen looking to improve food quality and service efficiency.