Bryant 3163 service manual Air Intake/Exhaust Assembly

Page 4

stitution will void the agencies’ certifications and the Norcold warranty. Refer to this manual for proper in- structions. Install the refrigerator and vents as directed by Norcold without modification.

The clearance from the refrigerator’s left side (facing the front of the refrigerator) to the vehicle’s exterior wall is important. This is the area in which the inlet and outlet flexible piping will be connected to the vent terminal housing during installation. Refer to Figures 3 and 4 for maximum clearances from refrigerator cabinet to vehi- cle exterior wall.

The wall thickness the vent terminal housing will accommodate is .030" minimum to 1.250" maximum. Figure 2 illustrates the configuration of the opening for the vent terminal housing. Do not make the opening in the vehicle wall larger than required. The clearance should be enough for the terminal housing to pass through the opening. If the opening is too large, the outer gasket will not cover the vent housing opening.

Figure 2 - Air Intake/Exhaust Assembly

1.

Mounting Screw

8.

O Rings

2.

Vent Cover

9.

Intake Piping

3.

Outer Disk

10.

Exhaust Piping

4.

Inner Disk

11.

Locking Washer Screw

5.

Rubber Gasket

12.

Locking Washer

6.

Vent Terminal

13.

Vehicle Exterior Wall

 

Housing Cut-Out

14.

Mounting Screw

7.

Vent Terminal

15.

Mounting Screw

 

Housing

 

 

It is imperative that the wall opening for the vent terminal housing not be too low. The flexible piping (inlet and outlet pipes) must rise from the refrigerator to the terminal housing. There are two specific vent-air intake assembly kits available to accommodate most installations. Figures 3 and 4 illustrate two installations with the maximum flexible piping lengths and the vent terminal housing locations.

Intake Pipe max. length 16"

Exhaust Pipe

max. length 14"

Figure 3 - Kit #617941 Flexible Piping & Vent Location

Intake Pipe max. length 21 3/4"

Exhaust Pipe

max. length

19 3/4"

Figure 4 - Kit #617943 Flexible Piping & Vent Location

3

Image 4
Contents Contents ModelImportant Safety Information Double-Wrenching Gas FittingsGeneral Information SpecificationsDirect Vent Requirements Air Intake/Exhaust Assembly Installing Refrigerator into the Enclosure Testing of the Vehicle’s Gas Supply PipingPropane System Insulating the Flexible Exhaust PipingDescription of Controls Lighting and Start-Up Instructions AC OperationDC Operation Shut-Down All ModesNorcold Limited Warranty Time Allowance Chart Heater WiresRialta EuroVanWiring Pictorial & Diagram Important Safety Information AC Circuit Specifications Refrigerator Will Not Operate on ACImportant Safety Information DC Circuit Refrigerator Will Not Operate on DC Electric Important Safety Information Gas Circuit No Spark at Burner Page Burner Ignites But Flame Will Not Hold Important Safety Information DC Fan Circuit Trouble Shooting Ventilation Fan Diagnosing Cooling Problems Diagnostic ProceduresRefrigerator Removal Procedures EuroVan CamperRialta Vent Kit Assembly Description Final Assembly Final Assembly Description Control Cover Assembly Description Control Assembly DescriptionBurner Box Assembly Description #$%

3163 specifications

Bryant 3163 is an advanced heating, ventilation, and air conditioning (HVAC) system that embodies the latest in HVAC technology and efficiency. Designed to meet the needs of modern homeowners, the Bryant 3163 offers a perfect blend of comfort, reliability, and energy savings.

One of the standout features of Bryant 3163 is its state-of-the-art variable-speed compressor. This technology allows the unit to adjust its output based on the specific demands of the environment, providing optimal comfort while minimizing energy consumption. Instead of running at a single, fixed speed like traditional systems, the variable-speed compressor can operate at different levels, ensuring a consistent and comfortable temperature throughout the home.

In addition to its impressive compressor, the Bryant 3163 is equipped with innovative multi-zone capabilities. This system allows homeowners to create separate climate zones within their homes, ensuring individualized comfort for different rooms or areas. This is particularly beneficial for larger homes where temperature preferences can vary widely between family members or activities in different areas.

The system also boasts an advanced air filtration system, which helps improve indoor air quality by capturing allergens, dust, and other airborne particles. The high-efficiency filters not only promote better health but also contribute to the overall efficiency of the HVAC system. Cleaner air means less strain on the system, leading to lower energy bills and an extended lifespan of the unit.

The Bryant 3163 incorporates smart technology, allowing homeowners to control their HVAC system remotely through smartphones or tablets. This feature enhances convenience, enabling users to adjust settings, monitor energy usage, and schedule maintenance with ease.

With a strong focus on energy efficiency, the Bryant 3163 meets stringent energy performance standards, qualifying for various efficiency rebates and incentives. Its quiet operation is another highlight, making it an ideal choice for residential environments where noise reduction is a priority.

In summary, the Bryant 3163 is a cutting-edge HVAC solution that excels in efficiency, comfort, and technology. With its variable-speed compressor, multi-zone capabilities, advanced air filtration, smart technology integration, and emphasis on energy savings, Bryant 3163 stands out as an excellent choice for homeowners seeking dependable climate control that prioritizes both comfort and efficiency.