Bryant 3163 Propane System, Insulating the Flexible Exhaust Piping, Gas Burner Flame

Page 5

Insulating the Flexible Exhaust Piping

The flexible exhaust pipe must be insulated prior to installation into the vent terminal housing. The flexible exhaust pipe connects to the flue tube of the refrigera- tor’s cooling unit and routes to the bottom opening of the vent terminal housing. Use the non-combustible insulation material supplied with the vent-air intake/ex- haust kit. Do not insulate the Air Intake pipe.

Installing Refrigerator into the Enclosure

Set the refrigerator into the enclosure and slide it back enough to connect the gas supply piping to the manual shut-off valve located at the top of the refrigerator. Connect the 12 volt DC supply to the terminal block also located at the top of the refrigerator. Connect the AC

power cord to the receptacle. Place the "O" rings onto the ends of both flexible pipes. Bend the flexible pipes so they clear the top of the enclosure. Connect the piping as follows:

Exhaust Pipe - This pipe is insulated and connects to the flue tube of the cooling unit. Route and connect to the bottom opening of the vent terminal housing.

Intake Pipe - This pipe is not insulated and connects to the burner cover. Route and connect to the top opening of the vent terminal housing.

Secure both flexible pipes to vent terminal housing with locking washer and screw. Slide refrigerator com- pletely into enclosure.

Propane System

Testing of the Vehicle’s Gas Supply Piping

When installation is complete, the propane gas supply piping must be inspected and tested for leaks from the refrigerator to the main gas supply tank. Use a leak detection solution. Do not test for leaks with an open flame.

If compressed air is used for leak testing, the pressure must not exceed 1/2 psig (14 inches water column).

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 1/2 psig (14 inches water column).

The appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressure less than or equal to 1/2 psig (14 inches water column).

Check the gas pressure to the refrigerator without other gas appliances operating. The pressure should not exceed 11 inches water column. With other appli- ances operating the pressure should not be less than 10.5 inches water column.

Gas Burner Flame

The gas operation of the refrigerator is controlled by the correct burner flame which supplies the heat input to the refrigerator’s cooling system. The correct burner flame is dependent upon correct input gas pressure and the burner and burner orifice being clean. The propane gas piping and the supply pressure must be inspected and tested at least twice a year. All inspec- tions and tests must be performed by the propane gas supplier or a qualified service agency.

A visual check of the burner flame should be made regularly. The burner flame can be observed through the air inlet grille as shown in Figure 5.

Burner Flame

Air Inlet Grille

Figure 5

As illustrated in Figure 6, the flame should be sharp blue with a stable burning appearance. If there is a constant yellow component observed or if the flame appears erratic and unstable, perform the following inspection. Check the gas supply pressure to insure the pressure is between 10.5" W.C. min. - 11" W.C. max.. Inspect the Air Intake pipe between the burner and the vent terminal housing for obstructions. If the gas supply pressure is within specifications, and the Air Intake pipe is clear of obstructions, clean the burner, orifice, and cooling unit’s flue tube. Also observe the position of the flame; it must be centered under the flue tube without touching the inner wall of the tube.

Figure 6

4

Image 5
Contents Model ContentsDouble-Wrenching Gas Fittings Important Safety InformationDirect Vent Requirements SpecificationsGeneral Information Air Intake/Exhaust Assembly Testing of the Vehicle’s Gas Supply Piping Installing Refrigerator into the EnclosurePropane System Insulating the Flexible Exhaust PipingDescription of Controls AC Operation Lighting and Start-Up InstructionsDC Operation Shut-Down All ModesHeater Wires Norcold Limited Warranty Time Allowance ChartRialta EuroVanWiring Pictorial & Diagram Important Safety Information AC Circuit Refrigerator Will Not Operate on AC SpecificationsImportant Safety Information DC Circuit Refrigerator Will Not Operate on DC Electric Important Safety Information Gas Circuit No Spark at Burner Page Burner Ignites But Flame Will Not Hold Important Safety Information DC Fan Circuit Trouble Shooting Ventilation Fan Diagnostic Procedures Diagnosing Cooling ProblemsEuroVan Camper Refrigerator Removal ProceduresRialta Vent Kit Assembly Description Final Assembly Final Assembly Description Control Cover Assembly Description Description Control AssemblyBurner Box Assembly Description #$%

3163 specifications

Bryant 3163 is an advanced heating, ventilation, and air conditioning (HVAC) system that embodies the latest in HVAC technology and efficiency. Designed to meet the needs of modern homeowners, the Bryant 3163 offers a perfect blend of comfort, reliability, and energy savings.

One of the standout features of Bryant 3163 is its state-of-the-art variable-speed compressor. This technology allows the unit to adjust its output based on the specific demands of the environment, providing optimal comfort while minimizing energy consumption. Instead of running at a single, fixed speed like traditional systems, the variable-speed compressor can operate at different levels, ensuring a consistent and comfortable temperature throughout the home.

In addition to its impressive compressor, the Bryant 3163 is equipped with innovative multi-zone capabilities. This system allows homeowners to create separate climate zones within their homes, ensuring individualized comfort for different rooms or areas. This is particularly beneficial for larger homes where temperature preferences can vary widely between family members or activities in different areas.

The system also boasts an advanced air filtration system, which helps improve indoor air quality by capturing allergens, dust, and other airborne particles. The high-efficiency filters not only promote better health but also contribute to the overall efficiency of the HVAC system. Cleaner air means less strain on the system, leading to lower energy bills and an extended lifespan of the unit.

The Bryant 3163 incorporates smart technology, allowing homeowners to control their HVAC system remotely through smartphones or tablets. This feature enhances convenience, enabling users to adjust settings, monitor energy usage, and schedule maintenance with ease.

With a strong focus on energy efficiency, the Bryant 3163 meets stringent energy performance standards, qualifying for various efficiency rebates and incentives. Its quiet operation is another highlight, making it an ideal choice for residential environments where noise reduction is a priority.

In summary, the Bryant 3163 is a cutting-edge HVAC solution that excels in efficiency, comfort, and technology. With its variable-speed compressor, multi-zone capabilities, advanced air filtration, smart technology integration, and emphasis on energy savings, Bryant 3163 stands out as an excellent choice for homeowners seeking dependable climate control that prioritizes both comfort and efficiency.