Bryant 3163 Norcold Limited Warranty Time Allowance Chart, Rialta, EuroVan, Heater Wires

Page 8

Norcold Limited Warranty Time Allowance Chart

Rialta

To gain access to the operating controls of the refrig- erator, remove the drawer directly above the refrigera- tor. The interrupter can be replaced without removing the refrigerator.

EuroVan

To gain access to the operating controls of the refrig- erator, remove the control panel assembly located directly above the refrigerator.

Heater Wires

To gain access to the AC and DC heater wires, remove the system cover located on the front left side of the refrigerator.

Time Allowance

Norcold will pay the time allowance multiplied by the service facility prevailing shop labor rate.

Note: The time allowances which follow include diagnostic times, defective part replace- ment, refrigerator removal and reinstallation (when applicable), and gas leak test times.

A gas leak test is required when gas connections, either the main supply line to the refrigerator or the refrigerator gas components, have been disconnected.

Note: In the event of a cooling unit failure, the complete refrigerator will be replaced. The time allotted to remove and replace the defective refrigerator will be 1 hr..

 

EuroVan

Rialta

Replacement Part

Time

Time

Allowance

Allowance

 

 

(Hours)

(Hours)

 

 

 

Burner

1.5

1.5

 

 

 

Burner Tube

1.4

1.4

 

 

 

Electrode Assembly

1.4

1.4

 

 

 

Heater - AC

1.3

1.3

 

 

 

Heater - DC

1.3

1.3

 

 

 

Flame Indicator Lamp

.3

.3

 

 

 

Interrupter

1.3

.5

 

 

 

Mode Selector Switch

1.3

1.3

 

 

 

Orifice

1.3

1.3

 

 

 

Relighter

.4

.4

 

 

 

Safety Valve

1.5

1.5

 

 

 

Thermocouple

1.5

1.5

 

 

 

Thermostat

1.6

1.6

 

 

 

Thermostat By-Pass

.3

.3

Screw

 

 

 

 

 

 

 

 

7

Image 8
Contents Contents ModelImportant Safety Information Double-Wrenching Gas FittingsDirect Vent Requirements SpecificationsGeneral Information Air Intake/Exhaust Assembly Installing Refrigerator into the Enclosure Testing of the Vehicle’s Gas Supply PipingPropane System Insulating the Flexible Exhaust PipingDescription of Controls Lighting and Start-Up Instructions AC OperationDC Operation Shut-Down All ModesNorcold Limited Warranty Time Allowance Chart Heater WiresRialta EuroVanWiring Pictorial & Diagram Important Safety Information AC Circuit Specifications Refrigerator Will Not Operate on ACImportant Safety Information DC Circuit Refrigerator Will Not Operate on DC Electric Important Safety Information Gas Circuit No Spark at Burner Page Burner Ignites But Flame Will Not Hold Important Safety Information DC Fan Circuit Trouble Shooting Ventilation Fan Diagnosing Cooling Problems Diagnostic ProceduresRefrigerator Removal Procedures EuroVan CamperRialta Vent Kit Assembly Description Final Assembly Final Assembly Description Control Cover Assembly Description Control Assembly DescriptionBurner Box Assembly Description #$%

3163 specifications

Bryant 3163 is an advanced heating, ventilation, and air conditioning (HVAC) system that embodies the latest in HVAC technology and efficiency. Designed to meet the needs of modern homeowners, the Bryant 3163 offers a perfect blend of comfort, reliability, and energy savings.

One of the standout features of Bryant 3163 is its state-of-the-art variable-speed compressor. This technology allows the unit to adjust its output based on the specific demands of the environment, providing optimal comfort while minimizing energy consumption. Instead of running at a single, fixed speed like traditional systems, the variable-speed compressor can operate at different levels, ensuring a consistent and comfortable temperature throughout the home.

In addition to its impressive compressor, the Bryant 3163 is equipped with innovative multi-zone capabilities. This system allows homeowners to create separate climate zones within their homes, ensuring individualized comfort for different rooms or areas. This is particularly beneficial for larger homes where temperature preferences can vary widely between family members or activities in different areas.

The system also boasts an advanced air filtration system, which helps improve indoor air quality by capturing allergens, dust, and other airborne particles. The high-efficiency filters not only promote better health but also contribute to the overall efficiency of the HVAC system. Cleaner air means less strain on the system, leading to lower energy bills and an extended lifespan of the unit.

The Bryant 3163 incorporates smart technology, allowing homeowners to control their HVAC system remotely through smartphones or tablets. This feature enhances convenience, enabling users to adjust settings, monitor energy usage, and schedule maintenance with ease.

With a strong focus on energy efficiency, the Bryant 3163 meets stringent energy performance standards, qualifying for various efficiency rebates and incentives. Its quiet operation is another highlight, making it an ideal choice for residential environments where noise reduction is a priority.

In summary, the Bryant 3163 is a cutting-edge HVAC solution that excels in efficiency, comfort, and technology. With its variable-speed compressor, multi-zone capabilities, advanced air filtration, smart technology integration, and emphasis on energy savings, Bryant 3163 stands out as an excellent choice for homeowners seeking dependable climate control that prioritizes both comfort and efficiency.