Carrier Container Refrigeration Unit manual Ca-Vs, Ca-Ve

Page 14

Table 1-5 Controlled Atmosphere (CA) Events Recorded in the DataCORDER -- Continued

Event

When Event Occurs

Data

Limits

 

Whenever O2 Air Cal-

New calibration value; Result

Last 2 per hour, last

O2 Air Calibration

(pass, fail, or low) Source (key-

ibration is completed

10 per day

 

 

pad, communications, or timer)

 

 

Whenever O2 Gas Cal-

New calibration value; Result

Last 2 per hour, last

O2 Gas Calibration

(pass or fail) Source (keypad,

ibration is completed

10 per day

 

 

communications, or timer)

 

 

Whenever CO Zero Cal-

New calibration value; Result

Last 2 per hour, last

CO2 Zero Calibration

2

(pass or fail, no gas) Source (key-

10 per day

ibration is completed

 

 

pad, communications, or timer)

 

 

Whenever the Tempera-

Type: normal, or active at mid-

 

Lockout Start

ture Controller initiates a

First 1 per hour

night

 

lockout of CA operation

 

 

 

 

 

 

 

 

 

Whenever the Tempera-

 

 

Lockout End

ture Controller enables

NA

Last 1 per hour.

 

CA operation.

 

 

CA Configuration

Any time the CA unit

Configuration variables

Last 2 per hour, last

Change

configuration changes

10 per day

 

 

 

N2 purity values for last low, me-

 

CA Nitrogen Test

Any time a nitrogen test

dium, and high flow tests, and

Last 2 per hour, last

flags to indicate whether low,

is completed

10 per day

 

medium and high values are in

 

 

 

 

 

range

 

 

Any time ‘‘service the fil-

Filter hours expired; filter hours

 

 

ter’’ hours or compressor

reset; compressor hours expired;

 

 

hours expires or is reset,

 

CA Service Activity

compressor hours reset; O2 sen-

First 1 per hour

or the O sensor’s life is

 

detected2to be low, or the

sor life low; O2 sensor expired;

 

 

O2 sensor is detected re-

filter, compressor, and total run

 

 

hours

 

 

placed

 

 

CA Software Upgrade

Any time the CA soft-

New software version

Last 1 per day

ware revision changes

 

 

 

 

Any time the CA Con-

 

 

CA Controller Replaced

troller serial number

New serial number

Last 1 per day

 

changes

 

 

Door Lock (CA-DL)

Any time the CA door is

NA

Last 1 per hour

locked by the Controller

 

 

 

 

Any time the CA door is

 

 

Door Unlock (CA-UL)

unlocked by the Control-

NA

Last 1 per hour

 

ler

 

 

Vent Mode Start

Any time CA vent mode

NA

Last 1 per hour

(CA-VS)

is initiated

 

 

Vent Mode End

Any time CA vent mode

NA

Last 1 per hour

(CA-VE)

is terminated

 

 

1-9

62-02575-07

Image 14
Contents Container Refrigeration Unit Operating Instructions Data Retrieval Table of Contents Table of Contents List of Illustrations Section Description Controller Expansion Module Micro-Link 1 Controller DataCORDER Capabilities Micro-Link 2 and Micro-Link 2i only DHS DHEBulbs EconsEcone BulbeCA-AL NWRCA-SP CA-PSCA-VS CA-VEUsda Recording Section System Setup Printer Support Section Dataview Program Instructions PRNTFILE.EXE DATAVIEW.EXERPTVIEW.EXE COREMON.EXEAdditional Steps For The HP Palmtop Topic 3 Menu Basics Topic 4 RAW File Conversion Topic 5 MICRO-LINKS Selection Screen Topic 6 Main Menu Screen Topic 7 Interrogation Menu Topic 8 Datareader Topic 9 System Tools Topic 10 Controller Utilities Control Setpoint This feature allows the user to view the compressor run time Topic 11 Controller Configuration Fixed Configuration Variables Custom Controller Configuration Topic 12 Recorder Utilities Configuration Date And Time Update ISO Trip Header Topic 13 Recorder Configuration Standard Configuration Generic Configuration Recorder Sensors Controller Sensors Topic 14 Probe Calibration Topic 15 Controller Monitor Topic 16 Program Setup Topic 17 Directory Screen Topic 18 Printer Setup Topic 19 View Data Topic 20 Sensor Configuration Caul CaalCadl CalsEvent Data ALT-R Next Report Topic 23 Print Data 62-02575-07 Section Optional Hardware Menu Interface Item. To select the desired item, press Configuration sub-menu Usda Cargo

Container Refrigeration Unit specifications

Carrier Container Refrigeration Units are essential components in the logistics and transportation of temperature-sensitive goods. These specialized refrigeration units ensure that perishable items, such as food, pharmaceuticals, and chemicals, maintain their required temperature throughout their journey, whether by sea, land, or air.

One of the primary features of Carrier Container Refrigeration Units is their advanced temperature control capability. These units can easily maintain temperature ranges from -30°C to +30°C, ensuring optimal conditions for various products. This flexibility is crucial for transporting diverse cargo, from frozen foods that require strict low-temperature settings to temperature-sensitive pharmaceuticals that may need to be kept at a steady room temperature.

Moreover, Carrier units are equipped with cutting-edge technologies aimed at improving efficiency and reliability. The use of electronic controls enhances the precision with which temperatures can be set and maintained. Integrated sensors continuously monitor conditions, allowing for real-time adjustments based on external temperature variations or changes in cargo load.

Carrier's eco-friendly refrigerants further underscore the company's commitment to sustainability. These units often utilize low Global Warming Potential (GWP) refrigerants that are less harmful to the environment, aligning with global regulations aimed at reducing greenhouse gas emissions.

Energy efficiency is another hallmark of Carrier Container Refrigeration Units. Many models incorporate high-efficiency compressors and evaporators, resulting in lower energy consumption compared to traditional refrigeration systems. This efficiency not only reduces operational costs but also contributes to a lower carbon footprint, making it an attractive option for environmentally conscious companies.

The design of these refrigeration units prioritizes durability and ease of maintenance. Robust construction materials withstand harsh maritime environments, minimizing the risk of damage during transit. Maintenance-friendly designs ensure that servicing is straightforward and can often be performed with minimal downtime, keeping logistics operations running smoothly.

In summary, Carrier Container Refrigeration Units combine advanced temperature control, energy efficiency, and sustainability with a focus on durability and ease of maintenance. Through innovative technologies and eco-friendly practices, Carrier continues to lead the way in providing reliable refrigeration solutions for the global supply chain, ensuring that temperature-sensitive goods reach their destination safely and efficiently.