A special type of recording is provided for USDA cold treatment purposes. Cold treatment recording requires that three remote temperature probes are placed in the cargo at various locations. Provision is made to connect these probes to the DataCORDER via receptacles located at the rear left-hand side of the unit. Four (five, on some units) receptacles are provided. Four (three-pin) receptacles are for the probes and one (five pin) receptacle is provided for the Interrogator. All receptacles are sized to accept a Deutsch HD16-5-16S size plug with a tricam coupling locking device. The DataCORDER inputs are designed to accept a two wire thermistor probe.

A label on the back panel of the unit shows which receptacle is used for each probe. The USDA #1, #2 and #3 probes (and possibly the optional Cargo probe) are installed in these receptacles.

The DataCORDER records up to six probe temperatures (supply, return, USDA #1, #2, #3 and an optional cargo probe #4), at the logging interval.

The standard DataCORDER report displays the supply and return air temperatures. The cold treatment report displays USDA #1, #2, #3 and return air temperatures. Cold treatment recording is backed up by a battery so recording can continue if AC power is lost.

NOTE

There may be an additional (3-pin) receptacle for a cargo probe on some units. This should NOT be used for USDA probes.

1.5 RELATIVE HUMIDITY

When the Relative Humidity Set Point mode is activated or de-activated (i.e., Controller function code Cd33 on Micro-Link 2/2i), this status is stored in the DataCORDER memory and reported as an event.

62-02575-07

1-10

Image 15
Contents Container Refrigeration Unit Operating Instructions Data Retrieval Table of Contents Table of Contents List of Illustrations Section Description Controller Expansion Module Micro-Link 1 Controller DataCORDER Capabilities Micro-Link 2 and Micro-Link 2i only DHE DHSBulbe EconsEcone BulbsCA-PS NWRCA-SP CA-ALCA-VE CA-VSUsda Recording Section System Setup Printer Support Section Dataview Program Instructions COREMON.EXE DATAVIEW.EXERPTVIEW.EXE PRNTFILE.EXEAdditional Steps For The HP Palmtop Topic 3 Menu Basics Topic 4 RAW File Conversion Topic 5 MICRO-LINKS Selection Screen Topic 6 Main Menu Screen Topic 7 Interrogation Menu Topic 8 Datareader Topic 9 System Tools Topic 10 Controller Utilities Control Setpoint This feature allows the user to view the compressor run time Topic 11 Controller Configuration Fixed Configuration Variables Custom Controller Configuration Topic 12 Recorder Utilities Configuration Date And Time Update ISO Trip Header Topic 13 Recorder Configuration Standard Configuration Generic Configuration Recorder Sensors Controller Sensors Topic 14 Probe Calibration Topic 15 Controller Monitor Topic 16 Program Setup Topic 17 Directory Screen Topic 18 Printer Setup Topic 19 View Data Topic 20 Sensor Configuration Cals CaalCadl CaulEvent Data ALT-R Next Report Topic 23 Print Data 62-02575-07 Section Optional Hardware Menu Interface Item. To select the desired item, press Configuration sub-menu Cargo Usda

Container Refrigeration Unit specifications

Carrier Container Refrigeration Units are essential components in the logistics and transportation of temperature-sensitive goods. These specialized refrigeration units ensure that perishable items, such as food, pharmaceuticals, and chemicals, maintain their required temperature throughout their journey, whether by sea, land, or air.

One of the primary features of Carrier Container Refrigeration Units is their advanced temperature control capability. These units can easily maintain temperature ranges from -30°C to +30°C, ensuring optimal conditions for various products. This flexibility is crucial for transporting diverse cargo, from frozen foods that require strict low-temperature settings to temperature-sensitive pharmaceuticals that may need to be kept at a steady room temperature.

Moreover, Carrier units are equipped with cutting-edge technologies aimed at improving efficiency and reliability. The use of electronic controls enhances the precision with which temperatures can be set and maintained. Integrated sensors continuously monitor conditions, allowing for real-time adjustments based on external temperature variations or changes in cargo load.

Carrier's eco-friendly refrigerants further underscore the company's commitment to sustainability. These units often utilize low Global Warming Potential (GWP) refrigerants that are less harmful to the environment, aligning with global regulations aimed at reducing greenhouse gas emissions.

Energy efficiency is another hallmark of Carrier Container Refrigeration Units. Many models incorporate high-efficiency compressors and evaporators, resulting in lower energy consumption compared to traditional refrigeration systems. This efficiency not only reduces operational costs but also contributes to a lower carbon footprint, making it an attractive option for environmentally conscious companies.

The design of these refrigeration units prioritizes durability and ease of maintenance. Robust construction materials withstand harsh maritime environments, minimizing the risk of damage during transit. Maintenance-friendly designs ensure that servicing is straightforward and can often be performed with minimal downtime, keeping logistics operations running smoothly.

In summary, Carrier Container Refrigeration Units combine advanced temperature control, energy efficiency, and sustainability with a focus on durability and ease of maintenance. Through innovative technologies and eco-friendly practices, Carrier continues to lead the way in providing reliable refrigeration solutions for the global supply chain, ensuring that temperature-sensitive goods reach their destination safely and efficiently.