Carrier Container Refrigeration Unit manual Topic 3 Menu Basics

Page 21

To modify the CONFIG.SYS file, the following entries must be in the CONFIG.SYS file to execute the DataView program:

i.DEVICE = \DOS\HIMEM.SYS

ii.DEVICE = \DOS\EMM386.EXE X=C800-CFFF I=DOOO-DFFF V

iii.DEVICE = \DOS\POWER.EXE

iv.DEVICE = \DOS\INTERLINK.EXE

v.DOS = HIGH, UMB

vi.FILES = 40

vii.BUFFERS = 30

The other entries should have “REM” entered before each entry. This will retain the information in the file, but the entry will not be executed. For example; the entry, “DEVICE = \PCM\DPMS.EXE” should be changed to “REM DEVICE = \PCM\DPMS.EXE.”

Running The Program At The MS-DOS Prompt

This section describes the procedure for executing the program from the MS-DOS prompt.

1.Reboot the computer into the MS-DOS mode. DO NOT start windows, this will reduce the amount of memory available for the Data View program.

2.Change directory to the DataView directory by typing: CD \DATAVIEW <ENTER> or CD \SCROLLDV <ENTER>

3.At the MS-DOS prompt type: DATAVIEW <ENTER> to run the program.

Changing Program Behavior

This section describes the two methods to change the behavior of the DataView program.

1)Start the DataView program and go to the Program Setup screen. From this screen the user can set up the program to run on their computer.

2)To add control parameters to the DataView main program, start at the MS-DOS prompt and type “directory -“pa- rameter” <ENTER> where “directory” is the resident directory (DATAVIEW, SCROLLDV or other directory des- ignation), then space dash and “parameter” is the parameter you want to change.

The following are valid parameters:

1.To set the temperature units to Celsius, type: “DIRECTORY” -TC <ENTER>.

2.To set the temperature units to Fahrenheit, type: “DIRECTORY” -TF <ENTER>.

3.To convert the RAW files to DCX files, type: “DIRECTORY” -CONVERT <ENTER>.

4.To run on monochrome monitors (i.e., HP Palmtop), type: “DIRECTORY” -P <ENTER>.

5.To run on color monitors, type: “DIRECTORY” -D <ENTER>.

6.To set the communications port (i.e., port where the Carrier module is connected), type: “DIRECTORY” -COM1 <ENTER> or “DIRECTORY” -COM2 <ENTER>

The above options can be combined. For instance, type: DATAVIEW -TF -D <ENTER> would set the reciprocating software program to run with Fahrenheit temperature units and a color monitor.

TOPIC 3 MENU BASICS

This section describes how to use the DOS DataView interrogator menu system.

Nearly the entire DataView Program can be run with these keystrokes:

1.RIGHT and LEFT Arrow keys move through the boxes on the screen.

2.UP and DOWN Arrow keys move vertically within a menu box.

3.ENTER selects an option.

4.ESC cancels the current screen and moves back to the previous screen.

5.H displays the help screen.

6.ALT-X exits the program and returns to the DOS prompt.

7.F9 attempts to reconnect the DataView program to the DataCORDER.

Throughout the program the user will be able to use the alphanumeric keys to select a feature without using the arrow keys. Upon pressing an alphanumeric key the selected feature is executed. In addition the user will be able to use the mouse to select a feature. Upon single clicking the left mouse button, the feature the pointer is on is executed.

62-02575-07

3-4

Image 21
Contents Container Refrigeration Unit Operating Instructions Data Retrieval Table of Contents Table of Contents List of Illustrations Section Description Controller Expansion Module Micro-Link 1 Controller DataCORDER Capabilities Micro-Link 2 and Micro-Link 2i only DHE DHSEcone EconsBulbs BulbeCA-SP NWRCA-AL CA-PSCA-VE CA-VSUsda Recording Section System Setup Printer Support Section Dataview Program Instructions RPTVIEW.EXE DATAVIEW.EXEPRNTFILE.EXE COREMON.EXEAdditional Steps For The HP Palmtop Topic 3 Menu Basics Topic 4 RAW File Conversion Topic 5 MICRO-LINKS Selection Screen Topic 6 Main Menu Screen Topic 7 Interrogation Menu Topic 8 Datareader Topic 9 System Tools Topic 10 Controller Utilities Control Setpoint This feature allows the user to view the compressor run time Topic 11 Controller Configuration Fixed Configuration Variables Custom Controller Configuration Topic 12 Recorder Utilities Configuration Date And Time Update ISO Trip Header Topic 13 Recorder Configuration Standard Configuration Generic Configuration Recorder Sensors Controller Sensors Topic 14 Probe Calibration Topic 15 Controller Monitor Topic 16 Program Setup Topic 17 Directory Screen Topic 18 Printer Setup Topic 19 View Data Topic 20 Sensor Configuration Cadl CaalCaul CalsEvent Data ALT-R Next Report Topic 23 Print Data 62-02575-07 Section Optional Hardware Menu Interface Item. To select the desired item, press Configuration sub-menu Cargo Usda

Container Refrigeration Unit specifications

Carrier Container Refrigeration Units are essential components in the logistics and transportation of temperature-sensitive goods. These specialized refrigeration units ensure that perishable items, such as food, pharmaceuticals, and chemicals, maintain their required temperature throughout their journey, whether by sea, land, or air.

One of the primary features of Carrier Container Refrigeration Units is their advanced temperature control capability. These units can easily maintain temperature ranges from -30°C to +30°C, ensuring optimal conditions for various products. This flexibility is crucial for transporting diverse cargo, from frozen foods that require strict low-temperature settings to temperature-sensitive pharmaceuticals that may need to be kept at a steady room temperature.

Moreover, Carrier units are equipped with cutting-edge technologies aimed at improving efficiency and reliability. The use of electronic controls enhances the precision with which temperatures can be set and maintained. Integrated sensors continuously monitor conditions, allowing for real-time adjustments based on external temperature variations or changes in cargo load.

Carrier's eco-friendly refrigerants further underscore the company's commitment to sustainability. These units often utilize low Global Warming Potential (GWP) refrigerants that are less harmful to the environment, aligning with global regulations aimed at reducing greenhouse gas emissions.

Energy efficiency is another hallmark of Carrier Container Refrigeration Units. Many models incorporate high-efficiency compressors and evaporators, resulting in lower energy consumption compared to traditional refrigeration systems. This efficiency not only reduces operational costs but also contributes to a lower carbon footprint, making it an attractive option for environmentally conscious companies.

The design of these refrigeration units prioritizes durability and ease of maintenance. Robust construction materials withstand harsh maritime environments, minimizing the risk of damage during transit. Maintenance-friendly designs ensure that servicing is straightforward and can often be performed with minimal downtime, keeping logistics operations running smoothly.

In summary, Carrier Container Refrigeration Units combine advanced temperature control, energy efficiency, and sustainability with a focus on durability and ease of maintenance. Through innovative technologies and eco-friendly practices, Carrier continues to lead the way in providing reliable refrigeration solutions for the global supply chain, ensuring that temperature-sensitive goods reach their destination safely and efficiently.