TOPIC 21 TEXTUAL DATA

The textual data display screen will display the interrogated data file on the screen. The data can be presented in the following ways: sensor data, event data, summary data and raw data.

Sensor Data

The sensor data is displayed in a tabular form, with the following columns:

1.Date

2.Time

3.Sensor 1

4.Sensor 2

5.Sensor 3

6.Sensor 4

7.Sensor 5

8.Sensor 6

9.Event Messages are displayed using acronyms to reduce space.

AL

- Controller Alarm

BULB_S - Bulb Mode Start

BULB_E - Bulb Mode End

CA_AL

- Controlled Atmosphere (CA) Alarm

CA_DL

- CA Door Lock

CA_UL

- CA Door Unlock

CA_LS

- CA Lockout Start

CA_LE

- CA Lockout End

CA_PS

- CA Pretrip Start

CA_PE

- CA Pretrip End

CA_SP

- CA Setpoint

CA_VS

- CA Vent Start

CA_VE

- CA Vent End

dAL

- Recorder Alarm

DS

- Defrost Start

DE

- Defrost End

DHS

- Dehumidification Start

DHE

- Dehumidification End

ECON_S - Economy Mode Start

ECON_E - Economy Mode End

HE

- Humidity End

HS

- Humidity Start

NEW SN

- New Controller

NEW SW

- Controller Software Upgrade

NWF

- Controller Communication Error

NWR

- Controller Communication Recovery

OFF

- Power Down

OFFwb

- Battery Backup Recording Start

ON

- Power Up

ONwb

- Battery Backup Recording End

PS

- Pretrip Start

PE

- Pretrip End

TS

- Trip Start

3-33

62-02575-07

Image 50
Contents Container Refrigeration Unit Operating Instructions Data Retrieval Table of Contents Table of Contents List of Illustrations Section Description Controller Expansion Module Micro-Link 1 Controller DataCORDER Capabilities Micro-Link 2 and Micro-Link 2i only DHS DHEBulbs EconsEcone BulbeCA-AL NWRCA-SP CA-PSCA-VS CA-VEUsda Recording Section System Setup Printer Support Section Dataview Program Instructions PRNTFILE.EXE DATAVIEW.EXERPTVIEW.EXE COREMON.EXEAdditional Steps For The HP Palmtop Topic 3 Menu Basics Topic 4 RAW File Conversion Topic 5 MICRO-LINKS Selection Screen Topic 6 Main Menu Screen Topic 7 Interrogation Menu Topic 8 Datareader Topic 9 System Tools Topic 10 Controller Utilities Control Setpoint This feature allows the user to view the compressor run time Topic 11 Controller Configuration Fixed Configuration Variables Custom Controller Configuration Topic 12 Recorder Utilities Configuration Date And Time Update ISO Trip Header Topic 13 Recorder Configuration Standard Configuration Generic Configuration Recorder Sensors Controller Sensors Topic 14 Probe Calibration Topic 15 Controller Monitor Topic 16 Program Setup Topic 17 Directory Screen Topic 18 Printer Setup Topic 19 View Data Topic 20 Sensor Configuration Caul CaalCadl CalsEvent Data ALT-R Next Report Topic 23 Print Data 62-02575-07 Section Optional Hardware Menu Interface Item. To select the desired item, press Configuration sub-menu Usda Cargo

Container Refrigeration Unit specifications

Carrier Container Refrigeration Units are essential components in the logistics and transportation of temperature-sensitive goods. These specialized refrigeration units ensure that perishable items, such as food, pharmaceuticals, and chemicals, maintain their required temperature throughout their journey, whether by sea, land, or air.

One of the primary features of Carrier Container Refrigeration Units is their advanced temperature control capability. These units can easily maintain temperature ranges from -30°C to +30°C, ensuring optimal conditions for various products. This flexibility is crucial for transporting diverse cargo, from frozen foods that require strict low-temperature settings to temperature-sensitive pharmaceuticals that may need to be kept at a steady room temperature.

Moreover, Carrier units are equipped with cutting-edge technologies aimed at improving efficiency and reliability. The use of electronic controls enhances the precision with which temperatures can be set and maintained. Integrated sensors continuously monitor conditions, allowing for real-time adjustments based on external temperature variations or changes in cargo load.

Carrier's eco-friendly refrigerants further underscore the company's commitment to sustainability. These units often utilize low Global Warming Potential (GWP) refrigerants that are less harmful to the environment, aligning with global regulations aimed at reducing greenhouse gas emissions.

Energy efficiency is another hallmark of Carrier Container Refrigeration Units. Many models incorporate high-efficiency compressors and evaporators, resulting in lower energy consumption compared to traditional refrigeration systems. This efficiency not only reduces operational costs but also contributes to a lower carbon footprint, making it an attractive option for environmentally conscious companies.

The design of these refrigeration units prioritizes durability and ease of maintenance. Robust construction materials withstand harsh maritime environments, minimizing the risk of damage during transit. Maintenance-friendly designs ensure that servicing is straightforward and can often be performed with minimal downtime, keeping logistics operations running smoothly.

In summary, Carrier Container Refrigeration Units combine advanced temperature control, energy efficiency, and sustainability with a focus on durability and ease of maintenance. Through innovative technologies and eco-friendly practices, Carrier continues to lead the way in providing reliable refrigeration solutions for the global supply chain, ensuring that temperature-sensitive goods reach their destination safely and efficiently.