TABLE 4 — METHODS FOR CLEANING STAINLESS STEEL

TASK

CLEANING AGENT*

METHOD OF

EFFECT ON FINISH

APPLICATION†

 

 

 

Routine Cleaning

Soap, ammonia or detergent and

Sponge with cloth, then rinse with

Satisfactory for use on all finishes.

 

water

clear water and wipe dry.

 

Stubborn Spots and Stains,

Revere Ware, Goddard’s, Twinkle,

Apply with damp sponge or cloth.

Satisfactory for use on all finishes if

Caked-on Splatter, and other

or Cameo stainless steel cleaner or

Rub with damp cloth.

rubbing is light. Use in direction of

Light Discolorations

Soft Scrub cleaner

 

polish lines.

 

Household cleansers, such as Old

Rub with a damp cloth. May contain

Use in direction of polish lines.

 

Dutch, Bon Ami, Ajax, Comet

chlorine bleaches. Rinse thoroughly

May scratch or dull highly polished

 

 

after use.

finishes.

Heat Tint or Heavy Discoloration

Revere Ware or Goddard’s stain-

Apply with damp sponge or cloth.

Use in direction of polish lines.

 

less steel cleaner

 

May scratch or dull highly polished

 

 

 

finishes.

Caked-on Foods and Grease,

Easy-Off oven cleaner

Apply generous coating. Allow to

Excellent removal. Satisfactory for

Fatty Acids Milkstone (where

 

stand for 10 to 15 minutes. Rinse.

use on all finishes.

swabbing or rubbing is not

 

Repeated application may be

 

practical)

 

necessary.

 

Hard Water Spots and Scale

Vinegar

Swab or wipe with cloth. Rinse with

Satisfactory for use on all finishes.

 

 

water and dry.

 

*Use of brand names is intended only to indicate a type of cleaner and does not constitute an endorsement; nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution and can be found in local supermarkets, depart- ment and hardware stores.

†All products should be used in strict accordance with instructions on package.

NOTES:

1.Use the mildest cleaning procedure that will do the job efficiently and effectively.

2.Always rub in the direction of polish lines for maximum effectiveness and to avoid marring the surface.

3.Use only a soft cloth, sponge, fiberous brushes, plastic or stainless steel pads for cleaning and scouring.

4.Rinse thoroughly with fresh water after every cleaning operation.

5.Always wipe dry to avoid water marks.

6.Never use common steel wool pads; these will cause rust!

15

Image 15
Contents Miracool Glass Door Merchandiser General ContentsInstallation Unit InspectionMiracool Bottle Cooler Unit Components Size 750L Shown „ to Remove Cartridge Level UnitCondensate Disposal Install ShelvesPreliminary Checks START-UPInitial START-UP „ Electrical Supply and ConnectionsUnit Data „ Liquid Control and Heat Exchanger Refrigeration System ServiceService and Troubleshooting Components„ Evaporator Compartment Interior top area Refer to Figures 10-12 for wiring diagrams Refrigeration System Service and Analysis ChartWiring DIAGRAM, Sizes 260L, 300L Wiring DIAGRAM, Size 750L Wiring DIAGRAM, Sizes 1100L, 1300L Maintenance Task Cleaning Agent Method Effect on Finish APPLICATION† Methods for Cleaning Stainless SteelCopyright 2006 Carrier Corporation

1300L, 260L specifications

The Carrier 260L and 1300L represent notable advancements in the realm of air conditioning systems, particularly designed for both commercial and industrial applications. These models are renowned for their efficiency, robust performance, and the integration of cutting-edge technologies.

The Carrier 260L is characterized by its remarkable energy efficiency, with a focus on reducing operational costs while maintaining optimal cooling performance. It is available in various capacities, making it suitable for a wide range of spaces, from medium-sized commercial installations to large-scale industrial facilities. The model incorporates advanced inverter technology, enabling it to adjust the compressor speed according to the cooling demand. This results in both energy savings and enhanced comfort, as the system can maintain a stable temperature with minimal fluctuations.

In contrast, the Carrier 1300L is tailored for larger industrial applications, offering even greater cooling capacities. This model is designed to tackle high thermal loads, making it ideal for factories, warehouses, and other large spaces where cooling requirements can fluctuate significantly. The 1300L also features robust construction principles, ensuring reliability and longevity even in demanding environments.

Both models share several key features that elevate their performance. They are equipped with eco-friendly refrigerants, aligning with global sustainability efforts. The units boast sophisticated control systems that allow for precise temperature management, remote monitoring, and integration with building management systems. This not only enhances user convenience but also promotes energy management strategies that are increasingly critical in today's energy-conscious world.

Moreover, the Carrier 260L and 1300L are designed with ease of maintenance in mind. Their modular components facilitate quicker access for service technicians, ensuring minimal downtime. Enhanced filtration systems improve indoor air quality, capturing dust and other particulates effectively, which is a key consideration in commercial settings.

In summary, Carrier's 260L and 1300L models stand out for their energy efficiency, advanced technology integration, and user-friendly features. They effectively meet the cooling challenges faced in commercial and industrial environments while adhering to sustainability goals, enhancing both user experience and operational efficiency. These systems exemplify Carrier's commitment to quality, reliability, and innovation in air conditioning solutions.