Carrier 260L, 1300L owner manual Contents, Unit Inspection, Installation, General

Page 2

CONTENTS

Page

GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 UNIT INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 LOCATE UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 LEVEL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALL SHELVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 CONDENSATE DISPOSAL. . . . . . . . . . . . . . . . . . . . . . . . . . 5

START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,7 PRELIMINARY CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 INITIAL START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

REFRIGERATION SYSTEM SERVICE . . . . . . . . . . . . 8-13 COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 SERVICE AND TROUBLESHOOTING . . . . . . . . . . . . . . . 8

MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14,15 LAMP REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 CONDENSATE REMOVAL . . . . . . . . . . . . . . . . . . . . . . . . 14 CONDENSER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 CABINET EXTERIOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 INTERIOR SURFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

UNIT INSPECTION

Examine all packages for damage to packaging mate- rial. Damage to external packaging may have resulted in unit damage. Check packages for all accessories and components, including legs, casters, and shelves. File a claim immediately with the shipping company if shipment is damaged or incomplete.

INSTALLATION

LOCATE UNIT

Refer to Figure 1 for unit components. Units are designed for indoor placement only. Provide at least

3 in. of space between unit cabinet and any adjacent wall or fixture. Remove skid base by removing the retaining screws (4 hex head bolt screws). If optional casters will be used, unit must be located on flat, level surface. Refer to Table 1 for a list of standard parts.

GENERAL

These instructions cover the installation, operation, and maintenance of Carrier Miracool™ series glass door merchandiser units, sizes 260L, 300L, 750L, 1100L, and 1300L.

TABLE 1 — STANDARD PARTS

 

FACTORY

FIELD

 

UNIT SIZE

 

PART

260L, 300L

750L

 

1100L, 1300L

INSTALLED

INSTALLED

 

 

 

Quantity

 

 

 

 

 

 

Refrigeration Cartridge

X

 

1

1

 

1

Shelves

 

X

4

5

 

10

Shelf Clips

 

X

16

20

 

40

Instruction Manual

1

1

 

1

Leveling Feet

X

 

4

4

 

4

Lamps

X

 

1

2

 

2

NOTE: Parts shown are for standard units. Quantity of shelves and clips may vary based on factory-supplied options.

2

Image 2
Contents Miracool Glass Door Merchandiser Unit Inspection ContentsInstallation GeneralMiracool Bottle Cooler Unit Components Size 750L Shown Level Unit „ to Remove CartridgeInstall Shelves Condensate DisposalSTART-UP Preliminary ChecksUnit Data Initial START-UP„ Electrical Supply and Connections Components Refrigeration System ServiceService and Troubleshooting „ Liquid Control and Heat Exchanger„ Evaporator Compartment Interior top area Refrigeration System Service and Analysis Chart Refer to Figures 10-12 for wiring diagramsWiring DIAGRAM, Sizes 260L, 300L Wiring DIAGRAM, Size 750L Wiring DIAGRAM, Sizes 1100L, 1300L Maintenance Methods for Cleaning Stainless Steel Task Cleaning Agent Method Effect on Finish APPLICATION†Copyright 2006 Carrier Corporation

1300L, 260L specifications

The Carrier 260L and 1300L represent notable advancements in the realm of air conditioning systems, particularly designed for both commercial and industrial applications. These models are renowned for their efficiency, robust performance, and the integration of cutting-edge technologies.

The Carrier 260L is characterized by its remarkable energy efficiency, with a focus on reducing operational costs while maintaining optimal cooling performance. It is available in various capacities, making it suitable for a wide range of spaces, from medium-sized commercial installations to large-scale industrial facilities. The model incorporates advanced inverter technology, enabling it to adjust the compressor speed according to the cooling demand. This results in both energy savings and enhanced comfort, as the system can maintain a stable temperature with minimal fluctuations.

In contrast, the Carrier 1300L is tailored for larger industrial applications, offering even greater cooling capacities. This model is designed to tackle high thermal loads, making it ideal for factories, warehouses, and other large spaces where cooling requirements can fluctuate significantly. The 1300L also features robust construction principles, ensuring reliability and longevity even in demanding environments.

Both models share several key features that elevate their performance. They are equipped with eco-friendly refrigerants, aligning with global sustainability efforts. The units boast sophisticated control systems that allow for precise temperature management, remote monitoring, and integration with building management systems. This not only enhances user convenience but also promotes energy management strategies that are increasingly critical in today's energy-conscious world.

Moreover, the Carrier 260L and 1300L are designed with ease of maintenance in mind. Their modular components facilitate quicker access for service technicians, ensuring minimal downtime. Enhanced filtration systems improve indoor air quality, capturing dust and other particulates effectively, which is a key consideration in commercial settings.

In summary, Carrier's 260L and 1300L models stand out for their energy efficiency, advanced technology integration, and user-friendly features. They effectively meet the cooling challenges faced in commercial and industrial environments while adhering to sustainability goals, enhancing both user experience and operational efficiency. These systems exemplify Carrier's commitment to quality, reliability, and innovation in air conditioning solutions.