Installation and Tapping – Concessionaire Dispensers
Connecting the Regulator to the CO2 Cylinder
■Remove blue plug from regulator fitting. (Note: Do not remove the carbonic washer).
■Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that
■Place a screw clamp over end of red air line and push onto regulator tailpiece. Tighten clamp with a screwdriver.
■Unscrew regulator from cylinder fitting.
■Replace carbonic washer (Part No. 157F2P), if needed and reattach regulator to filled cylinder.
■Turn CO2 hand valve counterclockwise until fully open. Turn regulator
■Adjust CO2 gas flow as required, turning clock wise for higher pressure.
Proper CO2 Handling
ALWAYS...
REGULATOR | HAND |
FITTING | |
CO2 | VALVE |
PRESSURE |
|
GAUGE |
|
30
20 40
PERLICK |
1050
■ | Connect a regulator (reducing valve) to |
| CO2 cylinder. |
■ | Secure cylinder in upright position whether in |
| storage or in use. |
PSI
0
FITTING FOR RED AIR HOSE
60
CO2
GAS
DRUM
REGULATOR
ADJUSTING
■ | Keep cylinder away from heat. Rupture disc |
| vents at 122° F. maximum. |
■ | Ventilate room after high pressure gas leakage. |
■ | Check the last DOT test date on cylinder neck |
| before filling. If more than five years old, the |
| cylinder must be retested to DOT specifications. |
■ | Be sure CO2 cylinder outlet fitting is free of dust |
| or dirt before attaching regulator. |
■ | Store CO2 cylinder and regulator assembly |
| upright. |
CLOSED POSITION)
■ Allow only properly trained and experienced |
personnel to handle high pressure gas. |
NEVER...
Adjusting the CO2 Gas Flow
■Turn regulator adjusting screw counterclockwise until it turns freely.
■Turn hand valve counterclockwise on CO2 cylinder to the fully open position.
■Turn regulator adjusting screw clockwise until desired pressure is reached (approximately
■Open
CO2 Leak Test
Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection.
Replacing CO2 Gas Cylinder
■Turn CO2 hand valve clockwise until seated and close
■Connect cylinder directly to a keg without a regulator (reducing valve).
■Drop or throw regulator or CO2 cylinder.
■Transport CO2 cylinder in a closed vehicle.
■Apply oil to a regulator.
■Shut off CO2 cylinder when not in use. You will not save gas by doing so!
■Allow untrained, inexperienced personnel to
handle high pressure gas.
Failure to heed this warning could result in personal injury or death.
WARNING/SAFETY INSTRUCTIONS
Beverage systems pressur- ized with carbon dioxide or nitrogen must be equipped with two safety relief valves; one at the cylinder regulator and the other in the gas line upstream on the product tanks.