Perlick DC Series specifications Preparing the Cabinet for Use Concessionaire Dispensers

Page 3

Preparing the Cabinet for Use – Concessionaire Dispensers

Parts List

Faucet Standard.

Faucet Head Assembly

Caster Set.

Black Connector Hose 316” x 3’.

516” Air Hose.

Spanner Wrench.

Bag of Miscellaneous Parts.

Tools Required

#2 Phillips Screwdriver.

Spanner Wrench (included).

#10 Crescent Wrench.

9/ 16” Allen Wrench.

3/ 8” Nut driver.

Uncrating and Inspection

Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is

not responsible for damage in transit.

Installing Casters

IMPORTANT: Attach casters to the cabinet bottom so that caster is centered over cabinet seam. Use supplied 1/ 4”- 20 x 3/ 4” hex head self-tapping machine screws.

Plumbing

None required. Garden hose connections for dumping liquid wastes.

Electrical

The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.

Installing the Faucet and

Dispensing Head

Before you begin: Wash dispensing head and faucet. Flush beer, dispensing head and faucet lines with fresh water.

Apply RTV around the base of the dispensing head to seal it to the top. Align the dispensing head over the five holes on the cabinet top and use the five stainless steel #10-32 x 134” Phillips pan head stainless steel machine screws to secure standard to cabinet top. Wipe off excess RTV to complete the seal.

Attach faucet to standard using spanner wrench to tighten coupling. Attach faucet handle to faucet.

Insert flexible plastic air hose six to seven inches into bottom of faucet standard. Secure hose with tie wrap (supplied).

CASTER MOUNTING

PLATE MUST

STRADDLE SEAM

COMPRESSOR

HOUSING

SCREWS

DRY

STORAGE

COMPARTMENT

CENTER CASTERS

CASTER MOUNTING

REQUIRED ON DC4KP

PLATE MUST

(4 KEG CONCESSIONAIRE)

STRADDLE SEAM

 

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

3

Form No. Z2060A

Rev. 12.05.03

Image 3
Contents Model NOS Sizes and Specifications, Concessionaire Dispensers Installation and Operating InstructionsPreparing the Cabinet for Use Concessionaire Dispensers Tapping a Single Valve Keg Sankey Installation and Tapping Concessionaire DispensersConnecting the Keg Coupler Important Be sure to close this valve when untapping kegCO2 Leak Test Connecting the Regulator to the CO2 CylinderAdjusting the CO2 Gas Flow Proper CO2 HandlingDraft Beer Information Concessionaire Dispensers TemperatureRefrigeration and Temperature Control Adjusting the temperatureCleaning the Beer System Concessionaire Dispensers Cleaning the CabinetCleaning the Condenser Step Cloudy Beer Trouble Shooting Concessionaire DispensersBeer Service Problems Wild Beer Flat BeerReplacement Parts Concessionaire Dispensers All ModelsCondensing units 2 door models For Single Valve Keg Coupler Series D MiscellaneousPart Description Wiring Diagram Concessionaire Dispensers