PROBLEM - C: Display does not start countdown when START key is touched.
1
Check: 1. TOUCH KEY BOARD (START KEY FUNCTION)
| Continuity | Check contact of |
| OK | connector S1 |
Check continuity of connector |
|
|
CN2 between Pin 1(PK) and |
|
|
pin 3(BL) when the door is |
|
|
closed | No | Adjust or replace door |
| ||
| continuity | sensing switch. |
Contact | Replace | Normal |
OK | Circuit board | circuit board |
Poor | Correct | Normal |
contact | seating | contact |
Normal Primary
switch
Runs
Runs
Runs
PROBLEM - D: Unit operation seems to be normal but little or no heating is produced in oven load.
|
|
| Check: 1. AIR VENTS |
| 1 | ||
|
|
| |
|
|
|
|
| Resistance | Replace H.V.C. | Normal H.V.C. |
| incorrect |
|
|
Normal | Measure resistance |
|
|
operation | of H.V.capacitor |
|
|
| (see page |
|
|
| Normal | Replace | Normal |
| resistance | magnetron | magnetron |
Check operation of fan | Resistance | Replace |
| |
motor when START key | Normal | |||
incorrect | fan motor | |||
is touched. | ||||
fan motor | ||||
|
| |||
No | 33 |
|
| |
operation |
|
|
| |
Measure resistance |
|
|
| |
of fan motor |
|
|
| |
Terminal A~C: 140 to 150 ohm | Normal | Replace | Normal | |
Terminal A~B: 25 to 40 ohm | resistance | circuit board | circuit board |
Runs
Runs
Runs
Runs