Part 2 PREPARE TO INSTALL THE RANGE
2
INSTALLATION DRAWINGS (LSE Series only)
NOTE
SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR.
CLEARANCES AND DIMENSIONS (Figure 1)
To install range refer to the following Figure 1.
For installation in CANADA, a
CAUTION CAUTION
•Make sure that the wall covering, countertop and cabinets around the range can withstand the heat (up to
194°F) generated by the range.
-Discoloration, delamination or melting may occur.
-This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194°F.
24” (60.9cm)
A = 30”(76.2 cm) For U.S.A
=30”(76.2 cm) ~ 31”(78.7 cm) For CANADA
FIGURE 1
MINIMUM DIMENSIONS (FIG. 2)
• Cabinet storage space located above the surface units should be avoided.
-The risk of burns or fire by reaching over heated surface units can be eliminated.
•Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets If
cabinet storage is to be provided.
- The risk can be reduced.
FIGURE 2
*30”(76.2cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24”(60.9cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4”(6.4cm) flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015”(0.381mm) stainless steel, 0.024”(0.610mm) aluminum or 0.020”(0.508mm) copper.
**15”(38.1cm) minimum between countertop and adjacent cabinet bottom.
5