LG Electronics LSE3092S, LRE3091S Part 3 Install the Range, Electrical Connection Requirements

Page 6

Part 3 INSTALL THE RANGE

3ELECTRICAL CONNECTION REQUIREMENTS

The range must be installed in accordance with Local and Canadian Electrical Codes (latest edition). See rating plate for total connected Amp rating. This model was shipped direct from the factory with Service cord attached. There are no range connections necessary.

Note: Cord replacement

Only a range cord rated at 40 amps with 120/240 minimum volt range is required. If a 50 amp range cord is used, it should be marked for use with 138” diameter connection openings.

4ANTI-TIP DEVICE INSTALLATION

WARNING

• DO NOT step or sit on the door. Install the Anti-Tip Bracket packed with range.

-The range could be tipped and injury might result from spilled hot liquid, food, or the range itself.

-If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti- Tip Device is properly reengaged when the range is pushed back against the wall.

Use a spirit level to check your adjustments. Place the level diagonally on the oven rack, and check each direction for level.

First check direction 1 .

After check direction 2 .

If the spirit level doesn’t show level on the rack, adjust the leveling legs with a wrench.

5FINAL INSTALLATION

Move range close enough to the opening to plug into the receptacle.

Slide range into position insuring that the left back leg slides under the anti-tip bracket. Range will sit 0” away from the back wall when properly installed.

Carefully tip range forward to insure that the anti-tip bracket engages the range back brace and prevents tip-over.

Turn on electrical power. Check range for proper operation as described in owner’s manual.

1.Locate the bracket using the template

An Anti-tip bracket is packaged with template. The instructions include necessary information to complete the installation.

Read and follow range installation instruction sheet (template).

2.Level the range

Level the range by adjusting the leveling legs with a wrench.

Optional rear filler

If the counter does not bridge the opening at the rear wall the rear filler kit, that is provided with the slide in range, will be needed.

NOTE : If the countertop depth is greater than 25” there will be a gap between the filler kit and the back wall.

If the countertop depth is less than 24”, the control panel will not sit flush with the countertop.

(See figure 1 on page 5)

6

Image 6
Contents Installation Manual Important Safety Instructions Before YOU BeginPrepare to Install the Range Part 2 Prepare to Install the Range Installation Drawings LRE Series onlyInstallation Drawings LSE Series only Final Installation Part 3 Install the RangeANTI-TIP Device Installation Electrical Connection Requirements