Liebert 3000 installation manual Glycool general arrangement

Page 44

Glycol/GLYCOOL Cooled Models

Figure 18 GLYCOOL general arrangement

 

Expansion Tank Field Installed at

 

 

 

Highest Point in System

 

 

Unions*

 

Fill *

Drycooler

Drycooler

 

 

 

 

 

 

Electric

 

 

 

 

Box

Coil

 

 

 

 

 

 

 

 

 

 

Fluid

 

 

 

Pressure

 

Return to

Isolation

 

Port*

Unions*

Pump

 

Valves*

 

 

Fluid

 

 

 

 

 

 

 

 

 

 

Supply

 

 

 

Hose

 

from

 

 

Air Vents*

 

Pump

 

 

Bib*

 

 

 

 

at Top of

Flow Regulating

Sight

 

 

 

Risers

 

Valve*

 

Glass

 

 

 

Pressure

 

 

 

Port*

Filter

Drier

Hot Gas

Bypass

Solenoid

Valve

Hot Gas

Bypass

3-Way Water

Regulating

FluidValve

Valve

Supply to

Glycol

Pump

Pump

Housing

Evaporator

Coil

Expansion

Valve

Sensing

Bulb

Hot Gas

Bypass External

Valve Scroll Equalizers

Compressor

Service

Valves

Econ-O-Coil

Tube

in Tube

Condenser

Unit

Actuator

Fluid

Econ-O-Cycle

 

Return

 

Comparator

 

from

 

Unit

Isolation

3-Way Chilled

 

 

Valves*

Glycol Valve

Econ-O-Coil

Circuit

Hose Bibs*

FACTORY PIPING

 

FIELD PIPING

 

*Components are not supplied by Liebert but

SL-11901 PG 5

are recommended for proper circuit operation and maintenance.

38

Image 44
Contents Liebert Challenger Page Table of Contents R407C Refrigerant Chilled Water ModelsSplit System Models Figures Tables System Descriptions Room Preparation Equipment InspectionLocation Considerations Equipment HandlingModel Lbs kg Unit net weightRemoval of Skid Rear return configuration Front return configurationFloor Cutout Dimensions Piping connection size Piping ConsiderationsDrain Line Hot GasRefrigerant Line HumidifierWater SupplyLine Suction Refrigerant LineCondensate Pump Line Condensate DrainCondenser SupplyLine Condenser Return LineHotWater Return HumidifierWater SupplyLine Hot Water SupplyPiping connections for chilled water self-contained units Installation Electrical Connections Electrical connectionsBalancing the Air Distribution Under-Floor Discharge SystemsHz Units 550 600 Model Ton Hz Units 550 600 ModelDucted Applications Checklist for Completed InstallationPlenum Installation Installation Condenser Location Line VoltageLow Voltage Lee-Temp/Flood Back Head Pressure Control CondensersAir cooled condenser statistics Refrigerant Piping Recommended line sizes OD copper inchesFan Speed Control Systems Materials SuppliedEquivalent lengths feet for various pipe fittings Condenser refrigerant per serial tagDehydration/Leak Test Single Circuit Shown Refrigerant control settings psi kPa Lee-Temp/Flood Back Head Pressure Control SystemsCharging PipingMaterials Supplied Low Pressure Cut Out High Pressure Cut Out 360 Single Circuit Shown Condenser Water cooled general arrangement Manual Flushing AdjustmentWater Regulating Valve Testing Valve Function Adjusting collar nutPump and Drycooler Drycooler InstallationDrycooler Location Dry Bulb Wet Bulb Relative Dew Point Humidity Room dew point temperaturesGlycol Piping Volume in standard Type L copper piping Filling InstructionsExpansion Tanks, Fluid Relief Valves and Other Devices Preparing the System for Filling@ 50F 10C Glycol SolutionsEthylene glycol concentrations Filling the System For expansion tank dimensions, see on 43-3/16 43-9/16 110 5mmSee Note 30-1/4 1095mm 483mm 1097mmMounting hole dimensional data Drycooler dataGlycol pump data Pump Pump Suction Pump Discharge ConnectionFactory Glycool general arrangement Glycol Regulating Valve Chilled Water Models WAY Valve Air Cooled Condensing Units Water/Glycol Cooled Condensing UnitsRefrigerant Loop Line coupling sizes Unit refrigerant chargeRecommended refrigerant lines R22 or R407C sizes OD copper Refrigerant piping diagram Quick Connect Fittings Unit Dimensions See Table Outdoor Air Cooled Condensing UnitsPFCZ42A-L PFCZ41A-L Outdoor air cooled condensing unit-top air discharge models See Table152 Piping and electrical connections top air discharge36-1/4 38-1/2 SL-11081 PG 8A Discharge ModelsInstalling the Indoor Condensing Unit Model Net Weight 60 Hz 50 Hz Lbs kgCentrifugal Air Cooled Condensing Units Indoor centrifugal condensing unitDetail of ceiling hanging bracket Ton DuctingAirflow CFM CMH Dimensional Data Piping Connections DPN000207Rev0 Ton centrifugal air cooled condensing unitTon centrifugal air cooled condensing unit dimensional data DPN000226Rev0 Water Cooled Water and Glycol Cooled Condensing Units Piping ConsiderationsCondenser Water Requirements Regulating ValvePiping Connections DPN000209Rev0 Ton water/glycol cooled condensing unit dimensional data DPN000228Rev0 Temperature Gauge Pressure Psig KPa R407C RefrigerantExample Temperature Pressure Gauge Psig KPaCalculating Subcooling R407C Refrigerant R407C Refrigerant Page Net ItiTin That
Related manuals
Manual 76 pages 7.19 Kb Manual 59 pages 52.87 Kb

3000 specifications

The Liebert 3000 is a cutting-edge power protection solution designed to provide reliable and efficient backup power for critical applications. This uninterruptible power supply (UPS) system is engineered to safeguard sensitive electronic equipment from power disturbances, ensuring uninterrupted operations in data centers, telecommunications, and industrial environments.

One of the standout features of the Liebert 3000 is its high-efficiency design. With an efficiency rating of up to 94%, the system minimizes energy loss, resulting in lower operational costs and a reduced carbon footprint. This is particularly important in today's environmentally conscious climate, as organizations strive to meet sustainability goals while maintaining top-tier performance.

The Liebert 3000 employs advanced technologies to enhance its functionality. It incorporates online double-conversion technology, which provides a continuous supply of clean and regulated power. This technology ensures that connected loads receive stable voltage and frequency, shielding them from voltage spikes, sags, and outages. Additionally, the UPS offers features such as automatic battery testing, which helps ensure peak battery performance and reliability.

Another key characteristic of the Liebert 3000 is its modular design, allowing for flexible scalability. This means that organizations can easily expand the capacity of their UPS system as their power needs grow, without the need for extensive system overhauls. The modular architecture also facilitates simplified maintenance and reduces downtime, as individual modules can be serviced without interrupting power to the critical load.

The system is equipped with comprehensive monitoring and management capabilities. The Liebert 3000 provides real-time data on power usage, battery status, and system performance, enabling facility managers to make informed decisions and proactively address potential issues. The integration of remote management tools allows for seamless monitoring from anywhere, providing peace of mind for operators.

Overall, the Liebert 3000 combines high efficiency, advanced technology, and flexible design to deliver a robust power protection solution. Its reliability and performance make it a preferred choice for organizations seeking to protect their critical infrastructure while enhancing operational efficiency and sustainability. As businesses continue to rely on technology for their everyday operations, the Liebert 3000 stands out as a dependable safeguard against the uncertainties of power quality.