Liebherr HC 2062, HCB 2062 installation instructions IceMaker

Page 11

IceMaker

4.Push the appliance slowly to the back wall until the compressor mounting plate makes contact with the anti-tipping bracket (Figure 15).

To prevent the appliance from tipping forward the compressor mounting plate must have contact with the anti tipping bracket (Figure 15).

Wall

Appliance

Anti - tipping bracket

Compressor mounting plate

Figure 15

5.Remove the cover from the valve connector (Figure 16).

6.The water line is visible at the front of the aplliance. Connect the water line with the OD adapter (Figure 16).

7.Bleed the air from the water line by opening the water supply temporarily.

8.Screw the OD adapter onto the solenoid valve (Figure 17).

Figure 16

Figure 17

9.Open the shut-off valve for the water supply and check the entire water system for leaks.

IMPORTANT

After starting up the appliance, the water pipe system must be purged of any air. Refer

to chapter "Bleeding the ice maker" in the operating instructions.

11

Image 11
Contents HCB Installation InstructionsPlease Read and Follow These Instructions Installation Guidelines Door swing clearence Figure Planning InformationCabinet Opening Dimensions Figure Panel Dimensions Inset Installation Style Figure Panel Dimensions Frameless Installation Style Figure Mounting the anti tipping device on wooden floors Blocking for SafetyMounting the anti tipping device on concrete floors Cover strips Figure Mounting the anti tipping device in cabinets deeper thanConnection to the Water Supply Safety Instructions and WarningsIceMaker IceMakerIceMaker Fasten the appliance in the recess InstallationAdjusting the front of the drawer Leveling the Appliance FigureMounting the attachment brackets onto the door panels Figure Mounting the refrigerator door Mounting the freezer drawerSoft-stop cylinder retracts in the detached state Installation Mounting the ventilation grille