Liebherr 7083-103-00 installation instructions Mounting the anti-tipping device, Water pressure

Page 8

Mounting the anti-tipping device

WARNING!

The supplied anti-tipping bracket must be installed in all cases. This prevents the appliance from tipping over when the fully loaded door is opened.

CAUTION!

Ensure that there are no electric cables or water pipes in the wall section to which the anti-tipping bracket is to be secured. These could be damaged during installation.

Important!

When securing the anti-tipping bracket to a concrete floor, use suitable plugs!

If the floor slopes down sideways, the anti-tipping bracket must be fitted horizontally. Lay down spacers in the appropriate positions.

1.Mark the centre line of the appliance on the floor. Align the anti-tipping bracket centre to the centre line.

Wall

2. Secure the anti-tipping bracket to the floor using the 3 screws (6 mm x 60 mm) included in the accessory pack.

The distance E between the leading edge of the body of the unit and the rear edge of the anti-tipping bracket is

Inset installation style > 610 mm + panel thickness Frameless installation style > 610 mm

Connection to the water supply

Safety instructions and warnings

Do not connect to the water supply while the combined refrig- erator-freezer is connected to the electricity supply.

The connection to the mains water supply may only be made by trained personnel.

The water quality must comply with the drinking water directives of the country in which the appliance is used.

The ice maker is designed exclusively to make ice cubes in quantities required by a household and may only be operated with water suitable for this purpose.

All repairs and work on the ice maker may only be carried out by customer service personnel or other trained personnel.

The manufacturer cannot accept liability for damage caused by a faulty connection to the mains water supply.

Water pressure

The water pressure must be between 150 and 600 KPa (1.5 - 6 bar).

Important! If the water filter is inserted in the appliance, the water pressure must lie between 300 and 600 KPa (3 - 6 bar).

If the water pressure with the inserted water filter is too low, this may cause the ice maker to malfunction.

The water supply to the appli- ance must be through a cold water pipe that can withstand the operating pressure and complies with the hygiene regulations.

For this, use the stainless steel hose supplied (length 3 m).

8

Image 8
Contents 7083 Electrical connection Setting upAppliance dimensions Appliance venting Installation dimensions Water shut-off tap must not sit directly above the socketDefinition of Inset Installation Style Definition of Frameless Installation StylePanel dimensions Inset installation style Door swing clearance Inset Installation Style Top ViewDoor swing clearance Frameless Installation Style Mounting the anti-tipping device Water pressureInstallation Adjusting the front of the drawer Levelling the applianceFasten the appliance in the recess Before fitting the door panelsMounting the attachment brackets onto the door panels Fig. aMounting the refrigerator panel Fig. BFig. G Mounting the ventilation grille Mounting the freezer panelsMounting the dust filter