Thermo Products OHFA199DV5B, OHFA199DV5R operation manual Psc Trouble Shooting, Diagnostic Features

Models: OHFA199DV5R OHFA199DV5B

1 78
Download 78 pages 14.24 Kb
Page 42
Image 42

PSC TROUBLE SHOOTING

DIAGNOSTIC FEATURES

The control board is equipped with 4 green Input Status LEDs and 1 red Board Status LED. These are intended to provide a quick view into furnace performance without requiring a voltmeter.

The green Input Status LEDs are driven by the “Y”, “W”, “G”, and “DEHUM” inputs and are located directly below those inputs. They will light to indicate the presence of these signals.

The red Board Status LED has two functions:

It will light when the board recognizes a valid input signal and will stay lit until all valid signals are removed. This is intended to show that the board is functioning and able to respond to input signals.

It will flash rapidly while 120VAC is missing from the LIMIT switch. This is intended to give a quick visual indication of the High Limit switch.

39

Page 42
Image 42
Thermo Products OHFA199DV5B, OHFA199DV5R operation manual Psc Trouble Shooting, Diagnostic Features