Thermo Products OHFA199DV5R, OHFA199DV5B operation manual

Models: OHFA199DV5R OHFA199DV5B

1 78
Download 78 pages 14.24 Kb
Page 63
Image 63

3.Check the resistance across the cad cell pins with the cell covered (protected from exposure to ambient light). The resistance should be greater than 20,000 ohms.

4.If cell resistances are different from above, replace the plug-in portion of cell, (Honeywell Part No. 130367).

5.Carefully reinsert the plug-in portion of the cad cell into the receptacle. If the cad cell appears to be functioning correctly, troubleshoot the fan control module and the safety and ignition control (primary control) module, according to the Honeywell instructions covering the devices.

The troubleshooting chart beginning on the following page should help identify the type of malfunction or deviation from normal operation. To use this diagram, just follow the instructions in the boxes. If the answer is yes or the condition is true, go down to the next box. If the answer is no or the condition is false, go to the box on the right. Continue checking and answering questions and conditions in each box until a problem and/or repair is found. After any maintenance or repair, the trouble shooting sequence should be repeated until normal system operation is achieved.

60

Page 63
Image 63