Liebherr 7083 461-00 Setting up, Electrical connection, Appliance venting, Door swing clearance

Page 2

Content

Page

Setting up

2

Electrical connection

2

Appliance venting

2

Door swing clearance

2

Appliance dimensions

3

Installation dimensions

3

Mounting the anti-tipping device

4

Mounting options

4

Connection to the water supply

5

Leveling the appliance

7

Fastening the appliance in the recess

7

Adjusting the refrigerator door

7

Adjusting the front of the drawer

7

Mounting the ventilation grille

8

Before fitting the door panels

9

Panel dimensions

9

Mounting the attachment brackets onto the door panels

10

Mounting the refrigerator panel

11

Mounting the freezer panels

13

Changing over door hinges

13

Setting up

Avoid positioning the appliance in direct sunlight or near cookers, radiators and similar sources of heat.

The floor on which the appliance stands should be horizontal and level.

The ventilation grilles should not be obstructed. Always ensure that there is good ventilation and that the outward flowing air is able to escape.

Standard EN 378 specifies that the room in which you install your appliance must have a volume of 1 m³ per 8 g of R 600a refrigerant used in the appliance, so as to avoid the formation of inflammable gas/air mixtures in the room where the appliance is located in the event of a leak in the refrigerant circuit. The quantity of refrigerant used in your appliance is indicated on the type plate on the inside of the appliance.

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type plate. The position of the type plate is shown in the description of the appliance.

The socket must be properly earthed and protected by a fuse. The tripping current of the fuse must be between 10 A and 16 A. The socket must not be situated behind the appliance and must be easily accessible.

Do not connect the appliance using an exten- sion cable or extension socket.

Do not use stand-alone inverters (conversion of direct current to alternating/three-phase cur- rent) or energy-saving plugs. Risk of damage to the electronic control system!

Appliance venting

The required air flow is directed through the plinth.

It is important to use the provided ventilation grille forthe ventilation opening.

This opening must not be cov- ered.

Failure to use the supplied grille can result in product failure and will void the warranty.

Door swing clearance

Please allow for door swing clearance at locations next to a wall.

The illustrated measurement is with- out mounted front panels.

Be sure to add your panel thickness and handle depth to this measure- ment in order to avoid interferences.

2

Image 2
Contents 7083 Appliance venting Setting upElectrical connection Door swing clearanceAppliance dimensions Installation dimensionsMounting the anti-tipping device Mounting optionsInstallation Water pressureBe sure the connection is tightly arranged Leveling the appliance Adjusting the refrigerator doorAdjusting the front of the drawer Fastening the appliance in the recessMounting the ventilation grille Panel dimensions Before fitting the door panelsMounting the attachment brackets onto the door panels Mounting the refrigerator panel Fig. aFig. E Mounting the freezer panels Changing over door hingesPage