Burner and nozzle characteristics
Table 1 |
|
|
|
|
| Liquid Gas |
|
|
| Natural Gas |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner | Diameter | Thermal Power | Nozzle | Flow* |
| Nozzle |
| Flow* | Nozzle | Flow* | ||||
| (mm) | kW (p.c.s.*) | 1/100 | 1/100 | g/h |
| 1/100 |
| l/h | 1/100 | l/h | |||
|
| Nominal |
| Reduced | (mm) | (mm) | *** |
| ** | (mm) |
|
| (mm) |
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fast | 100 | 3.00 |
| 0.7 | 41 | 87 | 218 |
| 214 | 128 |
| 286 | 143 | 286 |
(Large)(R) |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Semi Fast | 75 | 1.90 |
| 0.4 | 30 | 70 | 138 |
| 136 | 104 |
| 181 | 118 | 181 |
(Medium)(S) |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Auxiliary | 51 | 1.00 |
| 0.4 | 30 | 52 | 73 |
| 71 | 76 |
| 95 | 80 | 95 |
(Small)(A) |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Oven | - | 3.10 |
| 1.0 | 46 | 85 | 225 |
| 221 | 132 |
| 295 | 148 | 288 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Grill | - | 2.50 |
| - | - | 80 | 182 |
| 179 | 122 |
| 238 | 139 | 227 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply | Nominal (mbar) |
|
|
| 37 | 20 |
| 13 |
| |||||
Minimum (mbar) |
|
| 20 |
| 25 | 17 |
| 6,5 |
| |||||
Pressures |
|
|
|
|
| |||||||||
Maximum (mbar) |
|
| 35 |
| 45 | 25 |
| 18 |
| |||||
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*At 15°C and 1013 mbar- dry gas
** | Propane | P.C.S. = 50,37 MJ/Kg |
*** | Butane | P.C.S. = 49,47 MJ/Kg |
| Natural | P.C.S. = 37,78 MJ/m3 |