Refrigerated Lamps
Lamp Q150T3/CL Our Part No. 125-03-1081
Voltage 120VAC
Rated Life 1500 Hrs Manufacturer General electric
Our Cost $7.00 Telephone 1-800-554-4680

IGIP-DBP, DBRP 01,03-0210

Maintenance

BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

REPLACING FLUORESCENT LAMPS

Fluorescent lamps are furnished with a shatterproof pro- tective coating. The same type of lamp with protective coating must be used if replaced.

This lamp has been treated to resist breakage and must be replaced with a similarly treated lamp in order to maintain

compliance with NSF Standards.

NSF CODE 4.28.1

Contact HUSSMANN Chino for replacement

1-800-395-9229

x 2131

REPLACEMENT LAMP PART LIST

J220/230V150W/79

125-03-1141

220 VAC

1500 Hrs

Ushio America, Inc.

$2.55

1-800-760-7446

1-800-327-0097

General Electric has many national distribution loca- tions. Call for your closest location.

Ushio America Inc. is located at: 10550 Camden Drive.

Cypress, CA. 90630

T-5 BULBS

Please note:T-5 lights must be turned off and on after bulb replacement.

EVAPORATOR FANS

The evaporator fans are located at the center front of these merchandisers directly beneath the display pans. Should fans or blades need servicing, always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR.

COPPER COILS

The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers.

Hussmann recommends using #15 Sil-Fos for repairs.

TIPS & TROUBLESHOOTING

Before calling for service, check the following:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading. Overstocking case will affect its proper operation.

3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly, and that no outside doors or windows are open—allowing moisture to enter store.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial Number handy. This information is on a plate located on the case itself.

10

Image 10
Contents DBP, Dbrp 01,03 Island ProduceApparent Loss or Damage This Booklet Contains Information onShipping Damage Concealed Loss or DamageCut & Plan Views DBRP-03Uncrating the Stand InstallationLocation Exterior LoadingDo not USE Permagum Setting and JoiningLeveling Splash GuardWaste Outlet and P-TRAP Access PanelsInstalling Condensate Drain Hose ReelStat Location Wiring Color Code Ashrae Color CodeStocking Case CleaningCleaning Precautions When Cleaning Important StepsTips & Troubleshooting Replacing Fluorescent LampsElectrical and Refrigeration Specifications DBRP-01Electrical Schematics BALLASTB-232Diagram 22Remotemodelonly Type Typical Entering Refrigerator AIR Temperature AppendicesPotentially hazardous food Rev.0210 IGIP-DBP, Dbrp 01,03-0210 Limited Warranty Model Serial Number