hussman DBP, DBRP 01, 3 manual Appendices, Type Typical Entering Refrigerator AIR Temperature

Page 15

Rev.0210

Appendices

APPENDIX A. – Temperature Guidelines Refrigerated

The refrigerators should be operated according to the manufacturer’s published engineering specifications for entering air temperatures for specific equipment applications. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defrost and one hour after defrost for various categories of refrigerators. Refer to Appendix C for Field Evalua- tion Guidelines.

 

 

 

 

TABLE 1

 

 

 

TYPE OF

TYPICAL ENTERING

 

REFRIGERATOR

AIR TEMPERATURE

 

I. OPEN DISPLAY

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Non frozen:

 

 

 

 

 

 

 

 

 

 

 

 

1)

Meat

 

 

 

 

28°F

 

2)

Dairy/Deli

 

 

 

 

32°F

 

3)

Produce

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. Processed

 

 

 

 

36°F

 

 

 

 

b. Unprocessed

 

 

 

 

45°F

 

 

B. Frozen

 

 

 

 

0°F

 

 

C. Ice Cream

 

 

 

 

-5°F

 

II. CLOSED DISPLAY

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Non frozen:

 

 

 

 

 

 

 

 

 

 

 

 

1)

Meat

 

 

 

 

34°F

 

2)

Dairy/Deli

 

 

 

 

34°F

 

3)

Produce

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. Processed

 

 

 

 

36°F

 

 

 

 

b. Unprocessed

 

 

 

 

45°F

 

 

B. Frozen

 

 

 

 

0°F

 

 

C. Ice Cream

 

 

 

 

-5°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Deck

Multi Deck

ServiceCase

Reach-In

I. Open Display Styles

II. Closed Display Styles

APPENDIX B. – Application

Recommendations

Refrigerated

1.0Temperature performance is critical for controlling bacteria growth. Therefore, the following recommendations are included in the standard. They are based on confirmed field experience over many years.

1.1The installer is responsible for following the installation instruc-

tions and recommendations provided by the manufacturer for the installation of each individual type refrigerator.

1.2Refrigeration piping should be sized according to the equipment manufacturer’s recommendations and installed in accordance with normal refrigeration practices. Refrigeration piping should be insulated according to the manufacturer’s recommendations.

1.3A clogged waste outlet blocks refrigeration. The installer is responsible for the proper installation of the system which dispenses condensate waste through an air gap into the building indirect waste system.

1.4The installer should perform a complete start-up evaluation prior to the loading of food into the refrigerator, which includes such items as:

a)Initial temperature performance, Coils should be properly fed with a refrigerant according to manufacturer’s recommendations.

b)Observation of outside influences such as drafts, radiant heating from the ceiling and from lamps. Such influence should be properly corrected or compensated for.

c)At the same time, checks should be made of the store dry-bulb and wet-bulb temperatures to ascertain that they are within the limits prescribed by the manufacturer.

d)Complete start-up procedures should include checking through a defrost to make certain of its adequate frequency and length without substantially exceeding the actual needs. This should include checking the electrical or refrigerant circuits to make sure that defrosts are correctly programmed for all the refrigerators connected to each refrigeration system.

e)Recording instruments should be used to check performance.

APPENDIX C. – Field Recommendations - Refrigerated

Recommendations for field evaluating the performance of retail food refrigerators and hot cases

1.0The most consistent indicator of display refrigerator performance is temperature of the air entering the product zone (Refrigerated see Diagram 1, Appendix A). In practical use, the precise determination of return air temperature is extremely difficult. Readings of return air temperatures will be variable and results will be inconsistent. The product temperature alone is not an indicator of refrigerator performance.

NOTE: Public Health will use the temperature of the product in determining if the refrigerator will be allowed to display potentially hazardous food. For the purpose of this evaluation, product temperature above the FDA Food Code 1993 temperature for potentially hazardous food will be the first indication that an evaluation should be performed. It is expected that all refrigera- tors will keep food at the FDA Food Code 1993 temperature for

15

Image 15
Contents Island Produce DBP, Dbrp 01,03Concealed Loss or Damage This Booklet Contains Information onShipping Damage Apparent Loss or DamageDBRP-03 Cut & Plan ViewsExterior Loading InstallationLocation Uncrating the StandSplash Guard Setting and JoiningLeveling Do not USE PermagumHose Reel Access PanelsInstalling Condensate Drain Waste Outlet and P-TRAPStat Location Ashrae Color Code Wiring Color CodeImportant Steps Case CleaningCleaning Precautions When Cleaning StockingReplacing Fluorescent Lamps Tips & TroubleshootingDBRP-01 Electrical and Refrigeration SpecificationsBALLASTB-232 Electrical SchematicsDiagram 22Remotemodelonly Appendices Type Typical Entering Refrigerator AIR TemperaturePotentially hazardous food Rev.0210 IGIP-DBP, Dbrp 01,03-0210 Limited Warranty Model Serial Number