Installation Instructions
6CHECK IGNITION OF SURFACE BURNERS
Operation of all cooktop and oven burners should be checked after the range and gas supply lines have been carefully checked for leaks.
Electric Ignition Models
Select a top burner knob and simultaneously push in and turn to LITE position. You will hear a clicking sound indicating proper operation of the spark module. Once the air has been purged from the supply lines, burners should light within 4 seconds. After burner lights, rotate knob out of the LITE position. Try each burner in succession until all burners have been checked.
Quality of Flames
The combustion quality of burner flames needs to be determined visually.
(A) Yellow flames— Call for service
(B) Yellow tips on outer cones— Normal for LP gas
(C) Soft blue flames—Normal for natural gas
If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use.
With LP gas, some yellow tipping on outer cones is normal.
7CHECK IGNITION OF OVEN BURNER
The oven is designed to operate quietly and automatically. To operate the oven, press the BAKE pad and then press the number pads until 350° appears in the display. Touch the START pad. After
To check ignition of the broil burner, touch the BROIL HI/LO pad and then the START pad. After
Electric ignition models require electrical power to operate. In case of a power outage, the oven burners on these models cannot be lit manually with a match. Gas will not flow unless the glow bar is hot.
If the oven is in use when a power outage occurs, the burner will shut off and cannot be
51