5.Put items into the unit and close the door. Do not overstuff the unit or keep the door from closing.

6.Keep door closed during operation and re-close it quickly when adding items to the unit or removing items from it.

7.After use, press the Power pushbutton to turn OFF the unit then empty the unit.

8.Disconnect the power cord from the converter or accessory outlet and from the unit. Disconnect the converter from AC.

9.Clean unit as described in the Care & Maintenance section of this manual.

10.Store in a cool, dry area out of direct sunlight.

CAUTIONS

The unit can take up to 2 hours to reach its optimum set temperature if the set temperature is an operating extreme (approx. 40 °F to warm temperature 120 °F). It is recommended that items to be placed in the unit are at the correct temperature. This will assist the unit in reaching the desired temperature as quickly as possible

The unit will continue to operate as long as power is applied to it and it is turned ON.

If the vehicle engine is turned off, the unit will continue to draw power (a nominal 3.6-amps or 44 watts) from the vehicle battery.

If the engine is switched off for a long period (overnight) it is important to disconnect the unit from the accessory outlet to avoid draining the vehicle’s battery.

WARNINGS

Food will stay at desired temperature for some time after the unit is disconnected or turned off, but the temperature will eventually change to that of the surrounding air.

Observe common sense hygiene rules, as with any cooling/heating unit. Do not eat or drink perishable items that may have spoiled or become contaminated from lack of proper temperature control.

CAUTIONS

The unit is intended to maintain the temperature of pre-cooled or pre-heated food and beverages; it is not designed to warm cold items or to heat cold items.

CONNECTING TO THE SUPPLIED AC/DC CONVERTER

FIGURE 3 - VEC002 AC/DC Converter

PLUGS INTO REAR

 

OF COOLER

CONNECTING TO A PORTABLE 12 VOLT DC POWER SUPPLY

Insert the 12 volt DC plug on the power cord into the 12 volt DC socket on the portable power supply and the other end of the power cord into the receptacle on the rear of the cooler.

Continue operating the cooler/warmer as described under USE AS A COOLER WARMER.

Observe all CAUTIONS AND WARNINGS

Note: With a current draw of approximately 3.6 amps (44 watts), the unit will operate for approximately 1.2 hours from a fully charged 12 volt DC portable power supply, such as the Vector Pocket Power (Model #VEC018). A standard 19 Ampere Hour Jumpstarter/Power Supply such as the VEC021 or VEC020 series - can operate the cooler/warmer for approximately 4.8 hours.

CARE AND MAINTENANCE

The Mini Fridge Deluxe Cooler and Warmer is ruggedly constructed to provide years of dependable service.

After each use, clean the unit, inside and out, with a soft cloth and mild soap solution.

Do not scrape, scratch or puncture the surface of the unit with sharp objects or abrasives.

Dry the unit properly and store in a cool, dry place.

Always make sure the power cord and converter are disconnected before storing.

Never allow the unit to be immersed in liquid.

TROUBLESHOOTING

PROBLEM/POSSIBLE CAUSE/REMEDY

Accessory outlet of DC power supply is not functioning-check by plugging in a different (less than 4 amp) 12 Volt DC appliance. If not, clean accessory outlet and reconnect the Mini Fridge Deluxe Cooler and Warmer .

Fuse or circuit breaker in accessory outlet is open. Reset breaker or check fuse, and replace fuse if necessary. (See paragraph below)

Ignition is switched off - start engine or switch ignition to accessory position.

Fuse in unit’s DC power plug is blown - see Fuse Replacement section for location of fuse and instructions for checking and replacing fuse.

REFRIGERATOR/WARMER IS NOT COOLING OR HEATING PROPERLY (FAN IS NOT TURNING).

Fan is defective. Call Vector Customer Service Department for return/replacement instructions. This unit is not user-serviceable, it must be returned to Vector Manufacturing for professional service or repair. Any attempt to service by user will void warranty.

REFRIGERATOR/WARMER IS NOT COOLING OR HEATING, BUT FAN IS TURNING.

12 VOLT DC SOCKET

FUSED DC PLUG

Cooling unit is defective. Call Vector Customer Service Department for return/ replacement instructions. This unit is not user-serviceable, it must be returned to Vector Manufacturing for professional service or repair. Any attempt to service by user will void warranty.

Plug supplied Vector VEC0024 ampere converter’s power cord into standard 110 Volt 60 Hz outlet.

Insert the 12 Volt DC connector of the cooler/warmer into the socket on the converter.

Connect the other end of the cooler’s power cord into the polarized receptacle on the rear of the cooler.

Continue operating the cooler/warmer as described under USE AS A COOLER WARMER.

REFRIGERATOR/WARMER TAKES LONGER THAN 2 HOURS TO REACH DESIRED TEMPERATURE INSIDE.

Low battery or supply voltage. Check converter output.

Unit will attain desired temperature more efficiently if items are pre-heated or pre-chilled.

Fan area is blocked - Move unit or object.

5

6

Image 4
Contents Mini Fridge Deluxe Important Safety Information IntroductionCompletely Portable Important SuggestionsUSE AS Cooler or Warmer Front ViewConnecting to the Supplied AC/DC Converter Connecting to a Portable 12 Volt DC Power SupplyCare and Maintenance TroubleshootingLamp Replacement Fuse ReplacementSpecifications