Vinotemp VINO6500HZD, VINO4500HZD manual Humidity Adjustment

Page 15

2.The value of the set point will be displayed and the “°C” or “°F” LED starts blinking;

3.To change the Set value, push the keys or arrows within 10s.

4.To memorize the new set point value, push the SET key again or wait 10s.

4) Humidity Adjustment

The parameter Fon is used to adjust the humidity in the wine cabinet. The higher value of Fon, the higher relative humidity will be.

1.Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.

2.Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed.

3.Release the keys, select the required parameter Fon by up or down keys.

4.Press the “SET” key to display its value.

5.Use up or down keys to change its value.

6.The default value is 0, change high or low value to maintain high or low humidity.

7.Press “SET” to store the new value.

8.To exit: Press SET + or wait 15sec without pressing a key.

5) Regulation Differential

The parameter Hy is used as intervention differential for set point. Compressor cut-in is the set-point + Hy, and compressor cut-out is the set-point.

1.Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.

2.Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed.

3.Release the keys, HY will display immediately.

4.Press the “SET” key to display its value.

5.Use up or down keys to change its value.

6.The default value is 4, change high or low value to result in long high or short running cycle.

7.Press “SET” to store the new value.

8.To exit: Press SET + or wait 15sec without pressing a key.

6) Defrost Cycle

The parameter IdF is used as interval between defrost cycles.

1.Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.

2.Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed.

3.Release the keys, select the required parameter IdF by up or down keys.

4.Press the “SET” key to display its value.

5.Use up or down keys to change its value.

6.The default value is 24, change high or low value to result in less or more defrost cycle.

7.Press “SET” to store the new value.

8.To exit: Press SET + or wait 15sec without pressing a key.

- 14 -

Image 15
Contents WINE-MATECooling Unit Important Safety Information Table of Contents Feature Descriptions Feature DescriptionDimensions VINO1500-2500HZD Cabinet Installation Installation InstructionCabinet Cutout & Gasket LIP TOP Exhaust Gasket Cooling Unit VINO3500-8500HZD Through Wall Installation Through Wall Installation Electrical Cord Cellar ConstructionTemperature Setting Temperature Control & Humidity AdjustmentPage Humidity Adjustment Manual Defrost Drain Line Coil CleaningCare Guide Moisture RemovingTroubleshooting High or not HA alarmBlinking BeepingNoisy Water leakCircuit TrippingVINO1500-2500HZD Calling Feature Wiring Diagram VINO1500-2500HZD Wiring DiagramVINO3500-8500HZD Wiring Diagram Customer Support Warranty Limited WarrantyService under Warranty Limitation of Implied Warranty