6. “HA” alarm | a. | Improper room insulation & seal | a. | Check for insulation, gasket and | |||||||
blinking and | b. | Room too large |
|
| b. | door opening |
|
|
| ||
beeping, |
|
| Check for excessive size |
| |||||||
c. | Ambient temperature too high |
| c. | Check for installation location |
| ||||||
temperature |
|
| |||||||||
d. | Exhaust restricted |
|
| d. | Leave minimum 3 feet clearance for | ||||||
high or not |
|
|
|
|
|
| the exhaust side and leave | ||||
cooling and |
|
|
|
|
|
| minimum 1 foot clearance for the | ||||
running | e. | Malfunctioning fans |
|
| e. | fresh air intake side |
|
|
| ||
continually |
|
| Check for both evaporator and | ||||||||
|
|
|
|
|
| condenser fans |
|
|
| ||
| f. | Improper | evaporator | or | f. | Check for air restrictions |
| ||||
|
| condenser airflow |
|
| g. | Clean condenser |
|
|
| ||
| g. | Dirty Condenser |
|
|
|
|
| ||||
| h. | Iced evaporator |
|
| h. | Defrost and reset temperature |
| ||||
| i. | Refrigeration system restriction | i. | Call | service | for | checking | ||||
|
|
|
|
|
|
| restrictions |
|
|
| |
| j. | Refrigerant leak |
|
| j. | Call service for checking loss of | |||||
|
|
|
|
|
|
| refrigerant |
|
|
| |
| k. | Undercharge or overcharge |
| k. | Call service to add or remove | ||||||
|
|
|
|
|
|
| refrigerant |
|
|
| |
| l. | Failed components |
|
| l. | Check | compressor | windings, | start | ||
|
|
|
|
|
|
| relay and overload protector |
| |||
|
|
|
|
|
| ||||||
7.Unit running | a. Improper room insulation & seal | a. Check | for insulation, | gasket | and | ||||||
too long | b. Exhaust restricted |
|
|
| door opening |
|
|
| |||
|
|
| b. Leave minimum 3 feet clearance for | ||||||||
|
|
|
|
|
|
| the exhaust side and leave minimum | ||||
|
|
|
|
|
|
| 1 foot clearance for the fresh air | ||||
|
|
|
|
|
|
| intake side |
|
|
| |
| c. Room too large |
|
| c. Check for excessive size or increase | |||||||
|
|
|
|
|
|
| setting |
|
|
|
|
| d. Ambient | temperature | higher | > | d. Check | for installation | location or | ||||
|
| 90°F |
|
|
|
| increase setting |
|
|
| |
| e. Dirty Condenser |
|
| e. Clean condenser |
|
|
| ||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| |||||||
8.Fan motor | a. | a. | Check for fan running time FON | ||||||||
running but | b. | mode |
|
|
| b. | Check for proper voltage |
| |||
compressor | Incorrect power supply |
|
|
| |||||||
c. | Incorrect or loose wirings |
| c. | Check all wirings and connections | |||||||
not running |
| ||||||||||
d. | Failed components |
|
| d. | Check start relay, start capacitor, | ||||||
|
|
|
|
|
|
| overload protector, compressor. | ||||
| e. | Liquid | refrigerant | in | the | e. | Call service for OEM information. | ||||
|
| compressor |
|
|
|
|
|
|
|
| |
9.Compressor | a. | Fan blade stuck |
|
| a. | Check for proper clearance |
| ||||
running but | b. | Incorrect or loose wirings |
| b. | Check all wirings |
|
|
| |||
fan not | c. | Failed motors |
|
| c. | Call service for checking open or | |||||
|
|
|
|
|
| shorted windings |
|
|
| ||
running |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
10.Evaporator | a. | Evaporator air flow restriction |
| a. | Check for fans |
|
|
| |||
Icing | b. | Not stopping due to air leak, high | b. | Check for seal, door opening, | |||||||
|
| ambient | temperature | or low |
| ambient temperature and setting | |||||
|
| setting |
|
|
|
|
|
|
|
|
|
| c. | Low ambient temperature |
| c. | Defrost unit |
|
|
| |||
| d. | Bad thermostat or sensor |
| d. | Check for thermostat and sensor | ||||||
| e. | Moisture in the system |
|
| e. | Working initially then stopping |
|
- 18 -