Vinotemp WM2500 HTD-TE, WM1500 HTD-TE manual Humidity Adjustment

Page 11

3.2 How to change the set-point

1.Push the SET key for more than 3 seconds to change the Set point value;

2.The value of the set point will be displayed and the “°C” or “°F” LED starts blinking;

3.To change the Set value, push the keys or arrows within 10s.

4.To memorize the new set point value, push the SET key again or wait 10s.

4) Humidity Adjustment

The parameter Fon is used to adjust the humidity in the wine cabinet. The higher value of Fon, the higher relative humidity will be.

1.Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.

2.Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed.

3.Release the keys, select the required parameter Fon by up or down keys.

4.Press the “SET” key to display its value.

5.Use up or down keys to change its value.

6.The default value is 0, change high or low value to maintain high or low humidity.

7.Press “SET” to store the new value.

8.To exit: Press SET + or wait 15sec without pressing a key.

5) Regulation Differential

The parameter Hy is used as intervention differential for set point. Compressor cut-in is the set-point + Hy, and compressor cut-out is the set-point.

1.Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.

2.Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed.

3.Release the keys, HY will display immediately.

4.Press the “SET” key to display its value.

5.Use up or down keys to change its value.

6.The default value is 4, change high or low value to result in long high or short running cycle.

7.Press “SET” to store the new value.

8.To exit: Press SET + or wait 15sec without pressing a key.

6) Defrost Cycle

The parameter IdF is used as interval between defrost cycles.

1.Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.

2.Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed.

3.Release the keys, select the required parameter IdF by up or down keys.

4.Press the “SET” key to display its value.

5.Use up or down keys to change its value.

6.7. Press “SET” to store the new value.

8. To exit: Press SET + or wait 15sec without pressing a key.

- 10 -

Image 11
Contents WINE-MATECooling Unit Use & Care Manual Important Safety Information Table of Contents Feature Description Feature DescriptionCFM Cabinet Location Installation InstructionInstallation Located AT the Cabinet Electrical Cord TOP Exhaust GasketTemperature Setting Temperature Control & Humidity AdjustmentAlarm Signals Humidity Adjustment Manual Defrost Component Identification Care GuideIII. Moisture Removing II. Condenser Coil CleaningTroubleshooting Cooling BlinkingBeeping High or notNoisy Water leakCircuit TrippingCalling Feature Wiring Diagram Wiring DiagramCustomer Support Service under Warranty WarrantyLimited Warranty Limitation of Implied Warranty