4 Prepare Site
Your
IMPORTANT
• Unit can NOT be installed behind a closed cabinet door.
WARNING
SHOCK HAZARD — Electrical Grounding Required.
•Never remove the round grounding prong from the plug and never use a
•Never use an extension cord to connect power to the unit.
IMPORTANT
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.
See below for recommended receptacle location & cut out dimensions
2275DWRC Series
C2275DWR Series
24"
to
7"
Follow the
2275DWRW Series
24"
to
7"
24"
to
7"
Follow the
Follow the