Instructions for the installer
13.INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.
This appliance may be installed next to a wall which is higher than the appliance, as shown in the diagram showing the correct installation conditions. Any wall cupboards or shelves must be at a distance of at least 750 mm above the work surface.
13.1 Electrical connection
The I.D. plate with techinical data, registration number and brand name is visibily positioned in the storage compartment.
The plate must not be removed.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar
The connection terminals are located at the rear of the appliance. For electrical connections see following diagram. To access, remove the rear cover.
For operation on
For operation on
For operation on 220-240V : use an H05RR-F / H05RN-F /
The cable end to be connected to the appliance must be provided with an ground wire
17