Instructions for the installer
L.P.G. Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2.75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2.75kPa.
3.1Electrical connection
Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason.
The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded.
On the power line, install an omnipolar
Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must not be less than 0.75 mm2 (3 x 0.75 cable), keeping in mind that the end to be connected to the hob must have the ground wire
L = brown N = blue
=
The manufacturer will not be liable for any damage to persons or property caused by