Smeg PGFA95F manual Adaptation to Different Types of GAS, Replacement of nozzles on the hob

Page 12

Instructions for the installer

4. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the appliance from the electrical socket.

The cooker hob is set for natural gas NG (2H) at a pressure of 1.0 kPa. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

4.1Replacement of nozzles on the hob

This operation requires no primary air regulation.

1.Extract the grids and remove all the caps and flame-spreader crowns;

2.unscrew the burner nozzles with a 7 mm socket wrench;

3.replace the nozzles according to the type of gas to be used and the description in paragraph “3.2 Burner and nozzle characteristics table”.

4.Replace the burners in the correct position.

14

Image 12
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Instructions for the installer Installation of the ApplianceInstructions for the installer Attachment to support structure, flush-mounting model Figure, to avoid damage from overheatingInstructions for the installer Clearance above and around domestic appliances RequirementsRoom ventilation GAS Connection Discharge of combustion productsElectrical connection Replacement of nozzles on the hob Adaptation to Different Types of GASBurner and nozzle characteristics table Arrangement of burners on cooking hobAdjustment of minimum for natural gas Final OperationsLubrication of gas taps Instructions for the user USE of the Cooking HOBLighting the burners Practical advice for using the burners Diameter of containersCleaning and Maintenance Cleaning stainless steelCleaning of cooking hob components Problems and Causes Preventive maintenance