Instructions for the installer
15.2 Burner and nozzle characteristics table
| Rated heating |
|
|
|
|
|
|
|
Burner | capacity (kW) |
| LPG – G30/G31 28/37 mbar |
| ||||
|
|
|
|
|
|
| Flowrate |
|
|
| Nozzle | Reduced | Flowrate | ||||
|
| diameter 1/ | 1/100 |
| flowrate |
| g/h G30 | g/h G31 |
|
| 100 mm | mm | (W) |
|
|
| |
|
|
|
|
|
|
| 73 |
|
Auxiliary | 1.0 | 50 | 30 |
| 400 |
| 71 | |
Semi rapid | 1.8 | 65 | 33 |
| 500 |
| 127 | 125 |
Rapid | 3.0 | 85 | 45 |
| 800 |
| 218 | 214 |
4.0 | 100 | 65 |
| 1600 |
| 291 | 286 | |
|
|
|
|
|
|
|
|
|
Burner | Rated heating |
| NATURAL GAS – G20/G25 20/25 mbar |
| ||||
capacity (kW) |
|
| ||||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
| Nozzle diameter |
|
| Reduced flowrate | |||
|
|
| 1/100 mm |
|
| (W) |
| |
|
|
|
|
|
|
|
|
|
Auxiliary | 1.0 |
| 72 (X) |
|
| 400 |
| |
Semi rapid | 1.8 |
| 97 (Z) |
|
| 500 |
| |
Rapid | 3.0 |
| 115 (Y) |
|
| 800 |
| |
4.0 |
| 135 (K) |
|
| 1600 |
| ||
| 15.3 Arrangement of the burners on the hob |
|
|
|
| |||
|
|
|
|
| BURNERS | min. and max. Ø (in | ||
|
|
|
|
| ||||
|
|
|
|
|
|
|
| cm) |
|
|
|
|
| 1. Auxiliary |
|
| |
|
|
|
|
| 2. | 12 - 14 | ||
|
|
|
|
| 3. Rapid |
| 16 - 24 | |
|
|
|
|
| 4. | 18 - 26 | ||
|
|
|
|
|
|
|
| 18 - 26 |
|
|
|
|
|
|
|
|
|