Smeg PGFA95F-1 manual Clearance above and around domestic appliances, Requirements

Page 8

Instructions for the installer

2.3Clearance above and around domestic appliances

Extract from AS5601

REQUIREMENTS

1Overhead clearances – (Measurement A)

Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions. However, in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or, for an overhead exhaust fan, 750 mm.

Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with Clause 5.12.1.2. However, in no case shall this clearance to any surface be less than 450 mm.

10

Image 8
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Fixing the conventional built-in model to the structure Instructions for the installerInstallation of the Appliance Instructions for the installer Fixing the flush-top model to the structure Front Clearance above and around domestic appliances RequirementsRoom ventilation GAS Connection Discharge of combustion productsElectrical connection Plate for any reasonReplacement of nozzles on the hob Adaptation to Different Types of GASBurner and nozzle characteristics table Arrangement of burners on cooking hobLubrication of gas taps Adjustment of minimum for natural gasFinal Operations Lighting the burners Instructions for the userUSE of the Cooking HOB Practical advice for using the burners Diameter of containersCleaning of cooking hob components Cleaning and MaintenanceCleaning stainless steel Problems and Causes Preventive maintenance