Smeg PGFA95F-1 manual GAS Connection, Discharge of combustion products

Page 10

Instructions for the installer

2.5 Discharge of combustion products

Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration.

An efficient aspiration system requires careful planning by a specialist capable of installing it, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity.

3. GAS CONNECTION

This appliance is suitable for installation with Natural Gas or LPG (propane). Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of LPG (propane) appliances.

Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½” BSP connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be:

1.annealed copper pipe or;

2.flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm diameter.

The appliance must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply.

Before the appliance is operated make certain all relevant parts are placed in the correct position.

When the installation is completed the installation connections of appliance will require to be leak tested, the burner operating pressure and flame checked and adjusted.

Warranty service calls do not cover these adjustments!

To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. Ensure appliance is secured to wall when installation is completed.

N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted to 1.0kPa after installation.

12

Image 10
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Installation of the Appliance Instructions for the installerFixing the conventional built-in model to the structure Instructions for the installer Fixing the flush-top model to the structure Front Clearance above and around domestic appliances RequirementsRoom ventilation GAS Connection Discharge of combustion productsElectrical connection Plate for any reasonReplacement of nozzles on the hob Adaptation to Different Types of GASBurner and nozzle characteristics table Arrangement of burners on cooking hobFinal Operations Adjustment of minimum for natural gasLubrication of gas taps USE of the Cooking HOB Instructions for the userLighting the burners Practical advice for using the burners Diameter of containersCleaning stainless steel Cleaning and MaintenanceCleaning of cooking hob components Problems and Causes Preventive maintenance