Instructions for the installer

5.3 Regulation for G25/25 mbar

The hob has been inspected for G25 (2L) at a pressure of 25 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5.4 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

 

 

Rated heating

 

 

 

 

 

Burner

 

 

capacity

 

 

G25 25 mbar

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced flowrate

 

 

 

 

 

 

1/100 mm

 

 

(W)

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

 

1.05

 

76

 

 

380

 

 

 

 

 

 

 

 

 

Semi-rapid (2)

 

 

1.65

 

98

 

 

380

 

 

 

 

 

 

 

Rapid (3)

 

 

3.1

 

130

 

 

750

 

 

 

 

 

 

 

Double crown

 

internal (4)

 

1.05

 

76

 

 

380

 

 

 

 

 

 

 

 

 

internal (4)

 

3.9

 

150

 

 

1200

5.4Regulation of primary air

Referred to distance “X” in mm.

BURNER

 

G25

 

G30/G31

 

25 mbar

 

30/30 mbar

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

1.5

 

2.0

 

 

 

 

 

Semi-rapid (2)

 

1.5

 

2.0

 

 

 

 

 

Rapid (3)

 

2.0

 

9.0

 

 

 

 

 

Double crown

 

internal (4)

 

3.0

 

6.0

 

 

 

 

 

 

 

external (4)

 

3.0

 

10.0

 

 

 

 

(*) For burner reference numbers, see page 32.

30

Image 11
Contents Contents Instructions for Safe and Proper USE IntroductionPlate on the Casing Must not be Removed Attachment to support structure Instructions for the installerPositioning of HOB Instructions for the installer Plate for any reason Electrical ConnectionGAS Connection Discharge of combustion products Connection to LPGVentilation of rooms Removing the hob Adaptation to Different Types of GASRated BurnerheatingLPG G30/G31 30/30 mbar capacity Regulation for LPGRegulation of primary air Regulation for G25/25 mbarRegulation of minimum for LPG Final OperationsRegulation of minimum for natural gas This must be done by a qualified technician Arrangement of burners on hobLubrication of gas taps Ignition of the burners Using the HOBInstructions for the user Diameter of containers Practical advice for using the burnersUsing a griddle plate Regular daily cleaning of the hob Leaning and MaintenanceCleaning Cleaning of cooking hob componentsCover Ignition plugs and safety devicesElectric element