Instructions for the installer
3.5 Connection to gas
3.5.1 Connection with a rubber hose
Installation of the
Verify that all the following conditions are met:
•the hose is fixed to the hose connection with safety clamps;
•no part of the hose is in contact with hot walls (max. 50°C);
•the hose is not under traction or tension and has no tight curves or twists;
•the hose is not in contact with sharp objects or sharp corners;
•if the hose is not perfectly airtight and leaks gas, do not try and repair it: replace it with a new hose;
•verify that the hose is not past its expiry date (serigraphed on the hose itself).
CONNECTION USING RUBBER HOSES COMPLYING WITH THE CURRENT REGULATIONS IS ONLY PERMITTED IF THE HOSE CAN BE INSPECTED ALONG ITS ENTIRE LENGTH.
THE TIGHTENING TORQUE BETWEEN CONNECTIONS THAT INCORPORATE THE GASKET MUST NOT EXCEED 10NM
3.5.2 Connection to natural and LPG gas
Make the gas connection using a rubber hose in accordance to the regulations in force (verify if the mark of such norm is printed on the tube).
Accurately screw connector A to the gas tube B of the appliance ensuring to place gasket C in between. Place the rubber tube D on connector A and fix it with clip E conforming to the regulations in force.
9