Instructions for the installer
13. | INSTALLATION |
|
|
13.1 | Technical information |
|
|
Oven type | See rating plate |
| |
Electrical connections |
| ||
Required protection fuse for the oven | 30 Amps |
| |
OVEN RATING |
|
| |
Ovens |
| Electric |
|
Maximum electrical power | 6.1 kW |
| |
Oven grilling | Electric |
| |
Large grilling power | 3.0 kW (230 V) |
| |
Small grilling power | 1.8 kW (230 V) |
| |
Ovens lightings | 25 W (230 V) |
| |
OVEN CAVITY DIMENSIONS | Large oven | Small oven | |
Height (cm) | 34 | 23 | |
Width (cm) | 46 | 46 | |
Depth (cm) | 40 | 40 | |
Internal volume (cm2) | 62560 | 42320 | |
13.2 | The rating plate |
|
|
CHECK THAT MAINS VOLTAGE AND POWER CABLE RATINGS ARE AS PER THE INDICATIONS PROVIDED ON THE LABEL ATTACHED TO THE OVEN DOOR FRAME.
THIS LABEL MUST NEVER BE REMOVED.
Model | Serial N° |
13.3 Electrical connection
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH APPLICABLE REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN, FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD CAUSE OVERHEATING AND RISK OF BURNS.
IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.
24