Sub-Zero UC-24CI4 manual Top hinge adjustment Bottom hinge adjustment

Page 12

Undercounter Installation

12

 

 

Overlay Panel Installation

Hinge Adjustment

The model UC-24BG glass door is made with a sealed, double-wall tempered glass core. The drill must not contact this core when drilling. Be sure the hole is centered on the small groove in the front of the door frame and the drill passes squarely through the frame. If you are inexperienced with drilling, fasten the handle from the rear of the door panel only.

IMPORTANT NOTE: For model UC-24BG, install screws in all the mounting holes in the door frame. The nature of the door panel with a narrow outer rim and no connecting center member requires the support provided by the glass door.

After the door panel installation is complete, apply the cover patches or plugs provided over the holes on the inside surface of the door.

The cover patches or plugs are part of the insulation system on the door of the undercounter unit. Be sure to cover all the holes in the door that were used.

IMPORTANT NOTE: The undercounter unit should be properly leveled before door hinge adjustments are made.

The top and bottom cabinet hinges are held in place with three permanent adjustment screws. If the door needs adjustment, loosen the adjustment screws and reposition the door. Once in position, tighten the adjustment screws. Refer to the illustrations below.

TOP DOOR

 

HINGE

 

ADJUSTMENT

 

SCREWS

BOTTOM

DOOR HINGE

ADJUSTMENT

SCREWS

Top hinge adjustment.

Bottom hinge adjustment.

Image 12
Contents Undercounter Refrigeration Contents Important NoteLocation of rating plate Undercounter Specifications Undercounter Models Overall Dimensions Opening DimensionsSpecifications Site Preparation Before You Start Tools and Materials RequiredSite Preparation Electrical Requirements Plumbing RequirementsModel UC-24CI Undercounter Installation Unpack the Unit Anti-Tip BracketUndercounter Installation Install KickplateLevel the Unit Position the Unit Water Line Connection Model UC-24CIUndercounter Installation Door Panel Models UC-24R and UC-24CIBeverage Center Model UC-24BG Outdoor Model UC-24ROUndercounter Installation Overlay Panel Installation Tenon centers Door frame cross section Top hinge adjustment Bottom hinge adjustment Undercounter Installation Installation Checklist Service Information Page SUB-ZERO, INC. P. O. BOX 44848 MADISON, WI 53744 SUBZERO.COM