Site Preparation | 6 |
|
|
Electrical Requirements
The electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required.
IMPORTANT NOTE: The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall.
Model
Do not use an extension cord or
Plumbing Requirements
MODEL UC-24CI
For model
A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar).
A reverse osmosis system can be used, provided there is a consistent water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar) supplied to the water valve at all times. A copper line is not recommended for this application.
IMPORTANT NOTE: In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
Electrical Requirements
Power Supply | 115 V AC, 60 Hz |
Circuit Breaker | 15 amp |
Receptacle | |
|
|
Plumbing Requirements
Water Supply Line | 1/4" OD copper, braided stainless steel | |
|
| or PEX tubing |
Water Pressure |
| |
Excess Water Line for Connection | 26" (660) min |
LEFT SIDE |
OF OPENING |
2" (51) |
151/2" |
(394) |
3" (76) |
FRONT VIEW |
Location of electrical supply.
SHADED AREA
EXTENDS 1/2" (13)
FROM BACK WALL
2" (51)
151/2"
(394)
3" (76)
FRONT VIEW
Location of water supply.