Convection Steam Oven Specifications | 6 |
|
|
Electrical Requirements
IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610) for a standard installation or 25" (635) for a flush inset installation, the electrical supply for the convec- tion steam oven must be placed in an adjacent cabinet within reach of the 6' (1.8 m) power cord. Choose the elec- trical location shown in the illustrations on the following pages that best suits your installation.
IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
IMPORTANT NOTE: Performance may be compromised if the electrical supply is less than 240 volts.
A ground fault circuit interrupter (GFCI) is not recom- mended and may cause interruption of operation.
Electrical Requirements
ELECTRICAL SHOCK HAZARD: Plug into a grounded
To minimize shock hazard, the power cord must be plugged into a
Electrical Supply | 240/208 V AC, 60 Hz |
Service | 20 amp dedicated circuit |
Receptacle | NEMA |
Power Cord | 6' (1.8) |
|
|
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
NEMA
PLUG
3"
(76)
MINIMUM CORD
CLEARANCE
NEMA | Power cord clearance. |