Bridge Mono Transformer Coupled Output Wiring for 140V/200V Output Operation

The CP700 can be configured to drive 140V and 200V speaker lines.

Please observe all necessary safety precautions as the potential for electric shock at the speaker terminals is present.

With the CP700 turned off, move the rear mounted selector switch to the "Bridge" position and connect the input signal to channel one. Connect your speaker load across the "+" terminals of both output terminals as follows:

140V Operation - Connect the positive lead of the speaker load to the channel ONE 70V positive "+" terminal, the negative speaker lead connects to the channel TWO 70V positive "+" terminal. Connect a suitable jumper wire between the two terminals labeled "0." Consult your local codes to determine if Class I wiring is required (Figure 11).

200V Operation - Connect the positive lead of the speaker load to the channel ONE 100V positive "+" terminal, the negative speaker lead connects to the channel TWO 100V positive "+" terminal. Connect a suitable jumper wire between the two terminals labeled "0." Consult your local codes to determine if Class I wiring is required (Figure 12).

Caution! A high voltage potential exists across the two "+" speaker terminals when operating in any Bridge Mode application!

To 140V speaker load

CH-18, 4, and 2 Ohms

AUDIO TRANSFORMER CH-1

D I R . O U T P U T +

-

0

70 100 I S O L . O U T P U T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

-

+

 

-

+

 

 

 

 

 

 

70V

 

 

 

25V

 

 

 

 

 

 

BRIDGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONO

 

-

100V

+

 

 

 

 

CH-28, 4, and 2 Ohms

 

 

CH-2

 

AUDIO TRANSFORMER

D I R . O U T P U T +

-

0

70

100 I S O L . O U T P U T

 

 

 

 

 

 

 

 

 

-

 

-

+

 

-

+

 

 

 

70V

 

 

 

25V

 

 

BRIDGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONO

-

100V

+

 

 

 

 

 

Note Jumper

Figure 11

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •

TELEPHONE: (800) 876-3333

FAX: (800) 765-3435

©2005 ATLAS SOUND LP

Printed in U.S.A.

ATS002102 RevC 9/05

PP

13

Image 13
Contents CP700 Commercial Power Amplifier CP700 Commercial Power AmplifierSafety Instructions CP700 Commercial Power Amplifier Table of ContentsHearing Damage Shock HazardFeatures CP700 Commercial Power Amplifier IntroductionApplications Power Switch CP700 Commercial Power Amplifier Front Panel DescriptionProtect LED Indicators Signal Status LED IndicatorRear Panel Description 10. CH1/CH2, Low Impedance Speaker Outputs Stereo/Parallel/Bridge Switch11. CH1/CH2, 25/70.7/100V Speaker Outputs Calculating Constant Voltage LoadsBalanced Inputs CP700 Commercial Power Amplifier Input WiringUnbalanced Input Low Impedance Direct Coupled Output Stereo CP700 Commercial Power Amplifier Speaker Output WiringLow Impedance Direct Coupled Output Parallel Mono 25V, 70.7V, and 100V Transformer Output Wiring Bridge Mono Configuration Direct Coupled70.7V 25V100V CH-2 To 200V speaker load Direct Power OUT Protection Circuits CP700 Commercial Power Amplifier SpecificationsLimited Warranty